C O D A B A R I N F O
The CODABARINFO data structure contains scanner
configuration information about Codabar bar codes. To read
these values, applications call scnGetCodabarInfo; to set these
values, they call scnSetCodabarInfo.
typedef struct _CodabarInfo
{
unsigned char uchEnable;
unsigned char uchLength1;
unsigned char uchLength2;
unsigned char uchEnableCLSIEdit;
unsigned char uchEnableNOTISEdit;
} CODABARINFO;
Field
uchEnable
uchLength1
uchLength2
5-2
Programmer's Manual
Description
Enable/disable the ability to scan Codabar
bar codes.
Default: SCN_DISABLE
Specifies lengths (including start and stop
characters) for Codabar bar codes. You
can specify one or two lengths, a range of
lengths, or that any length is valid. Enter
values as follows:
Option
uchLength1 uchLength2
1 Length
Value
2 Lengths
Higher Value Lower Value
Range
Min. Value
Any length 0
Default: 5 (uchLength1) and 55
(uchLength2)
0
Max. Value
0