Sanyo MIR-162 Service Manual page 16

Hide thumbs Also See for MIR-162:
Table of Contents

Advertisement

F06:
F07:
F08:
F09:
F10:
F11:
Setting of service code
Step to F06 and input selectable value "384" or "000".
If you input "384", service code will be active.
If you input "000" (Factory default setting), service code will be
cancelled.
If there are no key operation, chamber temperature display will
appear. (Auto return)
Service code will be cancelled if main power is turned off after
inputting 384 or if you input "000".
Input service code "384" in F06 before utilizing F07.
Zero adjustment temperature in VR03 is displayed.
It is impossible to set zero adjustment value by control panel.
If there are no key operation for approx. 180seconds, chamber
temperature display will appear. (Auto return)
Input service code "384" in F06 before utilizing F08.
Input selectable value "000" or "001".
"000" = Filtered temperature (Factory default) is displayed
"001" = Unfiltered temperature is displayed
If there are no key operations for approx. 40seconds, chamber
temperature display will appear. (Auto return)
Input service code "384" in F06 before utilizing F09.
Input selectable value "000" or "001".
"000" = EEPROM data is uninitialized
"001" = EEPROM data excepting zero adjustment data is initialized
If there are no key operations for approx. 40seconds, chamber
temperature display will appear. (Auto return)
Input service code "384" in F06 before utilizing F10.
EEPROM version is displayed.
Press CALL key to display chamber temperature display.
Or if there are no key operations for approx. 40seconds, chamber
temperature display will appear. (Auto return)
Input service code "384" in F06 before utilizing F11.
Zero adjustment temperature can be set in F11.
Setting range; +19.9 to -19.9
Press CALL key to memorize the value and chamber temperature
display will appear.
If there are no key operations for approx. 40seconds, chamber
temperature display will appear.
- 13 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mir-262

Table of Contents