Test data

Note) Following data are the reference only, so they do not assure product's performance.

1. Pull-up test

Test condition: AT20
MIR-162
SV
When unit is stabilized ( )
Display
25.0
25
30.0
30
37.0
37
50.0
50
60.0
60
MIR-262
SV
When unit is stabilized ( )
Display
25.0
25
30.0
30
37.0
37
50.0
50
60.0
60
with 1 Plastic dish ( 90mm) placed in the center of chamber
1/2H air
Dish
Display
24.8
24.9
29.8
29.9
36.5
36.5
49.3
49.4
59.2
59.3
1/2H air
Dish
Display
25.1
25.0
30.2
30.0
37.3
37.3
50.3
50.3
60.6
60.6
Overshooting ( )
1/2H air
Dish
2.2
1.2
1.3
0
0.6
0
0.4
0
0.4
0
Overshooting ( )
1/2H air
Dish
1.3
0.2
0.4
0
0.4
0
0.5
0
0.5
0.1
- 16 -
Time to reach final
value +/-1
(Min.)
Display
1/2H air
0.7
43
38
0
29
22
0
21
52
0
39
72
0
43
85
Time to reach final
value +/-1
(Min.)
Display
1/2H air
0
35
22
0
19
58
0
24
82
0
49
97
0.1
68
104