Assembly of Brine tank:
The float assembly is a safety float; it only functions if there's a failure in the control valve.
This will insure the brine tank won't overflow with water. The safety float does not dictate the
water level in your brine tank. Measure from the top of the air check shown as # 1, 10" to
bottom of float show as #2 in photo below, you may have to gently push the float rod
through the rubber gametes to achieve this. Cut any existing rod off.
Slide the float assembly into the brine well shown in photo below and stick the stud into the
side hole on the brine well shown in photo below and secure it with the nut we supplied you.