Graco Reactor A-25 Repair Parts page 34

Plural-component sprayer
Hide thumbs Also See for Reactor A-25:
Table of Contents

Advertisement

Repair
Transformer Primary Check
1. Turn main power OFF
2. Locate the two smaller (10 AWG) wires coming out
of transformer. Trace these wires back to contactor
and circuit breaker (911). Use an ohmmeter to test
for continuity between two wires; there should be
continuity.
Transformer Secondary Check
1. Turn main power OFF
2. Locate the two larger (6 AWG) wires coming out of
transformer. Trace these wires back to large green
connector under hose control module and circuit
breaker (909). Use an ohmmeter to test for continu-
ity between two wires; there should be continuity.
If you are not sure which wire in green plug under
hose module connects to transformer, test both
wires. One wire should have continuity with the
other transformer wire in breaker (909) and the
other wire should not.
909
911
F
. 11: Circuit Breaker Module
IG
34
.
.
ti17999a
3. To verify transformer voltage, turn on hose zone.
Measure voltage from 178CB-2 to HPOD-1; see
Reactor A-25/A-XP1 Wiring Schematic, page 52.
Model
310 ft.
210 ft.
* For 230 Vac line voltage.
Replace Transformer
1. Turn main power OFF
supply.
2. Open Reactor cabinet.
3. Remove bolts holding transformer to cabinet floor.
Slide transformer forward.
4. Disconnect the transformer wires; see Reactor
A-25/A-XP1 Wiring Schematic, page 52.
5. Remove transformer from cabinet.
6. Install new transformer in reverse order.
Secondary Voltage
90 Vac*
62 Vac*
. Disconnect power
3A1570L