(2) Join the cover plates (right) and mount with screws
(Fig. 47).
Fig. 47
2. MOUNT THE COVER PLATE (LEFT)
(1) Join the cover plates (left) and mount with screws.
Fig. 48
Cover plate (left)
3. MOUNT THE INTAKE GRILLE
(1) Cut the right side of the intake grille. This is only
when the pipe exits from the right side (Fig. 49).
Fig. 49
(2) Insert the hinges on the bottom of the intake grille
into the holes in the base assembly. Then mount the
arms to the three areas on the top of the intake grille
(Fig. 50).
Fig. 50
11. CUSTOMER GUIDANCE
Explain the following to the customer in accordance
with the operating manual :
(1) Starting and stopping method, operation switching,
temperature adjustment, timer, air flow switching,
and other remote controller operations.
(2) Air filter removal and cleaning, and how to use the
air louvers.
(3) Give the operating and installation manuals to the
customer.
– –