Fig. 34
Electric component box
Remove the four
tapping screws.
Do not remove the screws. If the stays
are removed, the electric component box
will fall.
(2) Pull out the electric component box.
Fig.35
(3) Remove the electric component box cover.
Fig.36
Base
Remove the three tapping screws.
Be careful not to pinch the lead wires
between the electric component box and
base.
Electric component box
Electric component box
(4) Wiring
[Heat & Cool model (Reverse cycle)]
1) Remove the cord clamp.
2) Process the end of the connection cords to the
dimensions shown in Fig. 37.
3) Connect the end of the connection cord fully into
the terminal block.
Fig. 37
Terminal block
4) Fasten the connection cord with a cord clamp.
5) Fasten the end of the connection cord with the
screw.
[Cooling model]
1) Remove the cord clamp.
2) Process the end of the connection cords to the
dimensions shown in Fig. 38.
3) Connect the end of the connection cord fully into
the terminal block.
Fig. 38
Terminal block
4) Fasten the connection cord with a cord clamp.
5) Fasten the end of the connection cord with the
screw.
– –
– 154 –
Connection
cord
Cord clamp
Power cord
Connection
cord
Cord clamp
Power cord