SERVICE MODE

C. Setup Procedures
1. Displaying SERVICE MODE screen
Display Service Mode screen following the instructions "How to
enter Service Mode" above.
2. Displaying Internal Setup screen
Push NEXT button within three seconds after operating the Service
Mode display.
On the Internal Setup screen shown on the right, set up Market and
Region.
Model
DCS-TS750/US
DC-TS750/XE
DC-TS750/UK
DC-TS750/CA
DC-TS730/CA
Market/Rejion setup table.
3. Setting Market code
3.1. While a highlighted indicator is displayed on the right side of the
Market denotation, push ENT button on the remote controller.
With each push the indicator will advance as shown below.
WM -> SFC -> EUR -> S18 -> SS -> PA
3.2. Specify the code of the model in accordance with the Market/
Region Setup Table above.
(In DWM-380 model, the code is the same as the initial one
"WM". Advance to the next procedure without making any
changes.)
3.3 Once the desired code is displayed, push p button to move the
highlighted indicator to the Region input area.
Market
Region
SFC
1
EUR
2
EUR
2
S18
1
S18
1
- 10 -