TROUBLESHOOTING GUIDE

No.
1
Leaks at quick connect fittings.
2
3
Leaks at quick tubing.
All light go out.
4
5
No water flow from the water
filtration faucet.
6
Water flow from the water filtration
7
faucet becomes small.
Filtered water tastes strange or like
8
chlorine bleach.
1
2
3
4
5
6
7
8

PERFORMANCE DATA SHEET

· System tested by Kohler in accordance with NSF / ANSI
Standard 42&53 for the reduction of substances listed
below.
K-5339T-
Model
KT100
Particulate
Chlorine/
Taste & odor
Lead
Mercury
Cyst*
VOC
(volatile organic
compounds)
Capacity (gallon)
800
Flow rate(gpm)
0.75
Cyst : Giardia Cysts or Cryptosporidium Oocysts. It is a
common infectious protozoon with diameter of about 0.5-1um.
1211428-T01-A
Symptom
Tubing is not pushed to the backstop.
Tubing is not straight and smooth.
Tubing is cracke or scratched.
Batteries is exhausted.
The main water line valve is closed.
The tubing is crimped or sharp
bended.
The filtration cartridge is blocked.
Service life of carbon block cartridge
runs out.
K-5339T-
K-5339T-
KT200
KT400
1000
2000
0.75
0.75
Probable Cause
·
Standard 42&53
K-5339T-
KT500
/
*
(gallon)
3500
(gpm)
0.8
0.5-1
-8-
Solution
Reinsert tubing into push-in fitting as
far as it will go.
Recut tubing.
Simply cut that portion away and
reinsert tubing into push-in fitting.
Replace the batteries.
Check and open it.
Keep the tubing straight.
Replace the cartridge.
Replace the cartridge.