Paradyne HOTWIREt 7984 User Manual page 72

M/hdsl standalone termination unit with dsx-1 interface
Hide thumbs Also See for HOTWIREt 7984:
Table of Contents

Advertisement

Messages and Troubleshooting
6-6
Table 6-2. Troubleshooting (2 of 2)
Symptom
Possible Cause
Not receiving data.
The network or data port
cables are not
connected (check front
panel LEDs for more
information).
A test is being executed
on the unit (check the
TEST LED on the front
TEST LED on the front
panel).
The far-end unit is
off-line.
The far-end unit is
running a test.
An alarm condition exists
in the far-end unit.
Power-Up Self-Test
The unit has detected an
fails. Only Power
internal hardware failure.
and Alarm LEDs are
on after power-up.
February 1999
Solutions
Check network and data port
cables.
Run Loopback tests. Refer to
Chapter 5,
Stop the test or wait for the test to
end.
l)
Make sure the far-end device is
on.
Stop the far-end test.
Check the far-end Health and
Status messages.
Reset the unit and try again.
Contact your service
representative.