Paradyne HOTWIREt 7984 User Manual page 51

M/hdsl standalone termination unit with dsx-1 interface
Hide thumbs Also See for HOTWIREt 7984:
Table of Contents

Advertisement

7984-A2-GB20-10
This Field . . .
Contains . . .
Current Interval
The number of seconds which have elapsed in the current
Timer
15-minute interval. Maximum value is 900 seconds (15 minutes).
This counter resets every 15 minutes.
Payload Rate
The Payload Rate across the DSL interface.
DSL Line Rate
The rate of the DSL line (400 to 1552 kbps).
Current Interval
Performance data for the current 15 minutes.
Interval xx
Historical performance data for up to 96 15-minute intervals
(24 hours) where the value of xx is from 01 to 96.
Network Performance Statistics are collected for:
Mrgn: Margin, the signal-to-noise ratio (SNR) less an SNR reference value.
XmtPw: The transmit power level.
RxGn: The receiver gain level.
Complete: Whether the interval register contains data for a complete
900-second interval.
February 1999
Monitoring the Unit
4-9