Wall-hung condensation gas boiler with stainless steel water-heater (104 pages)
Summary of Contents for Lamborghini Caloreclima ALMA 24 MBS W TOP
Page 1
CALDAIA MURALE A GAS CON BOLLITORE AD ACCUMULO - ALTO RENDIMENTO - MODULANTE WALL-MOUNTED GAS BOILER WITH STORAGE WATER HEATER - HIGH EFFICIENCY - MODULATING CALDERA MURAL DE GAS CON INTERCAMBIADOR DE ACUMULACIÓN - ALTO RENDIMIENTO - MODULANTE 24 MBS W TOP 28 MBS W TOP 32 MBS W TOP LIBRETTO DI INSTALLAZIONE E MANUTENZIONE...
Page 2
... on your excellent choice. Thank you for choosing our products. LAMBORGHINI CALORECLIMA is daily committed to seeking innovative technical solutions to satisfy every need. Constant presence of our products on the Italian and international markets is assured by a widespread network of Agents and Dealers assisted by “LAMBORGHINI SERVICE”...
GENERAL SAFETY WARNINGS AND RULES • The instruction manuals provided form an integral part of the boiler and consequently must be carefully kept and must ALWAYS accompany the boiler, even in the case of transfer to another owner or user or transfer to another system. In the event of damage or loss, request another copy from your local Technical Service.
GENERAL DESCRIPTION The boilers operate fully automatically and the gas flow is controlled by an electronic control unit with the following cha- racteristics: - continuous modulation on both circuits - possibility of adjusting the heat output - possibility of adjusting slow ignition. The models are equipped with: - no-water pressure switch - full safety thermostat...
GENERAL MAIN COMPONENT STRUCTURE ALMA MBS W TOP Sanitary water expansion tank Water heater sensor Heating expansion tank. Delivery sensor Circulator 3-way electric valve Safety flow switch Modulating coil Gas valve 10 Sanitary water unit - 8 bar safety valve - Flow regulator - Check valve - Inspection filter 11 Stainless steel water heater...
GENERAL DIMENSIONS mm Ø 80 split Ø 100 concentric Ø 80 intake CIRCULATOR Output/head available to the system Flow rate (l/h) Minimum safety flow switch activation ∆P 1,2 m. - ...
GENERAL TECHNICAL DATA DESCRIPTION ALMA 24 MBS W TOP Fuel Gas supply pressure (nominal) 28-30 mbar Boiler category II2H3+ Type of boiler B22 - C12 - C32 - C42 - C52 - C62 - C82 maximum Nominal heating power (Qn) minimum 12,1 maximum 24,36 Useful nominal output (Pn) minimum 10,68...
Page 9
GENERAL DESCRIPTION ALMA 28 MBS W TOP Fuel Gas supply pressure (nominal) 28-30 mbar Boiler category II2H3+ Type of boiler B22 - C12 - C32 - C42 - C52 - C62 - C82 maximum 30.4 Nominal heating power (Qn) minimum 14.2 maximum 28.45 Useful nominal output (Pn) minimum 12.6 Max/min useful efficiency at Pn...
Page 10
GENERAL DESCRIPTION ALMA 32 MBS W TOP Fuel Gas supply pressure (nominal) 28-30 mbar Boiler category II2H3+ Type of boiler B22 - C12 - C32 - C42 - C52 - C62 - C82 maximum 34.5 Nominal heating power (Qn) minimum maximum 32.4 Useful nominal output (Pn) minimum 12.19 Max/min useful efficiency at Pn...
GENERAL IDENTIFICATION The ALMA boiler is identifiable by the labels on the packaging and the TECHNICAL DATA PLATE found inside the boiler as shown in the figure. WARNING • Tampering with, removing, missing identification plates or anything else that does not allow certain identification of the product makes any installation and maintenance operation difficult.
GENERAL HYDRAULIC CIRCUIT 13 Burner Sanitary hot water outlet 14 Expansion tank Sanitary cold water inlet 15 Automatic air escape valve 16 Circulator System return 17 Heating safety valve System delivery 18 Safety flow switch Magnesium anode 19 Filling cock Water heater sensor 20 3-way electric valve Water heater...
GENERAL CONTROL PANEL The ALMA boilers are equipped with the instruments shown below. Boiler status display P1 Boiler function selection button (Summer/Winter - ON/OFF) P2 Cyclic function selection P3 Heating temperature increase button P4 Heating temperature decrease button P5 Sanitary water temperature increase button P6 Sanitary water temperature decrease button The display shows 3 digits and some symbols that indicate the boiler operating mode.
GENERAL DISPLAY BUTTON FUNCTION SYMBOL Pressing the button for 3 seconds the following functions are displayed: Summer Summer ----> Winter Holding the button pressed down for 3 seconds the boiler switches off. Winter Pressing the button the following information is cyclically displayed: flashing Sanitary water temperature Heating temperature...
GENERAL PARAMETER PROGRAMMING Simultaneously press the buttons P2 and P3 for 10s to access the programming menu where the left digit indicates the parameter number, and the centre and right digits the parameter value. When the programming menu has been accessed, the left digit will blink; use the P3 and P4 buttons to change the para- meter number, and the P5 and P6 buttons to change the value which will immediately be stored.
GENERAL WARNINGS For each operating mode one or more symbols appear on the LCD display. In the event of a fault, the display will show a code whose meaning is summarised in the following table: Fault Code Failed ignition lock Safety thermostat intervention lock No water Air pressure switch (MCS)/flue gas thermostat (MC)
Page 17
GENERAL HEATING PUMP ANTI-LOCKING FUNCTION An anti-locking function activates the circulator for 30 seconds every 24 hours of inactivity. Following a power failure, the first anti-locking intervention occurs after 1 hour of inactivity. The function is active even when operation is locked and the selector is set to OFF.
Page 18
GENERAL FAN AND AIR FLOW CHECK (MBS MODELS) If an ignition request is received, the system checks for the absence of air flow (contact open) of the flue gas pressure switch, and if the test is passed the fan is activated. When air flow is detected (contact closed) the ignition sequence is started.
Page 19
GENERAL HEATING MODE WITH EXTERNAL SENSOR (OPTIONAL) Operation is the same as in normal heating mode with the difference that the delivery temperature is calculated in relation to the external temperature read by the sensor and the K factor. The K factor is set with the P3 and P4 buttons. HEATING TEMPERATURE INCREASE BUTTON HEATING TEMPERATURE DECREASE BUTTON External temperature (°C)
Page 20
GENERAL OPERATION WITH REMOTE CONTROL (OPTIONAL) The boiler can be operated with a RC03.54 remote control. The RC03.54 remote control is an intelligent hourly programmer complete with ambient sensor suitable for adjustment and control of wall-mounted gas boilers for heating and production of sanitary hot water mainly for installation in residential buildings.
GENERAL WIRING DIAGRAMS ALMA MBS W TOP BLACK WHITE Burner Delivery sensor Circulator Water heater sensor Display Ambient thermostat Ignition electrode Safety thermostat Combustion control electrode 3-way valve MVG Gas valve modulator Air pressure switch Gas valve Safety flow switch (water) Line Resistor Neutral External sensor (optional) Ignition transformer...
Page 22
GENERAL INTEGRATED FLAME CONTROL Electronic flame control unit intended for direct ignition of the main burner by means a capacitive discharge spark generator and flame detection control by means of the ionisation phenomenon. OPERATING SEQUENCE When the request contact is closed and after checking for the presence of air (MBS) or closure of the flue gas thermostat (MB), the self-test starts during which the flame amplifier and the components associated with safety functions are tested.
INSTALLATION PRODUCT RECEIPT The boiler is delivered packed in one protective cardboard box. The bag (A) inside the cardboard box contains the following material: - Installation and maintenance manual - User’s manual - System manual - Warranty certificate - Hydraulic test certificate - Exploded diagram of spare parts - Paper fitting template.
INSTALLATION HYDRAULIC CONNECTION After securing the support hooks, position the template so that it sits flush with the wall. Starting from the end unions previously fitted on the template, proceed with installation of all the pipes: system delivery, system return, cold water, hot water, and possibly also gas and electric line with ambient thermostat.
INSTALLATION INSTALLATION The boiler must be installed by qualified persons. The installation must be in conformity with the provisions of the law regarding evacuation of the combustion products in accordance with the REGULATIONS IN FORCE. The combustible gases must be evacuated through a pipe with a diameter not less than that on the boiler and it must be connected to a flue suited to the system capacity.
INSTALLATION TURNING ON FILLING THE SYSTEM Slowly open the feed cock until the system reaches a pressure of 1.5 bar indicated on the hydrometer and then close it. Check that the cap on the automatic air escape valve positioned on the circulator is loosened, and repeatedly activate the circulator to release the air in the circuit.
INSTALLATION FLUE GAS EXHAUST CONNECTION The boiler operates by combustion in a sealed chamber and therefore does not require any particular ventilation, and can also be housed in compartments, storerooms, technical spaces, etc. There are also various possibilities for exhaust of the combustion products and intake of air from the outside.
Page 28
Ø 87 mm Baffle NO Baffle Ø 82 mm (standard hole) Baffle for coaxial pipes Fit the baffle on the 60Ø aluminium stub pipe of the upper boiler flange. WARNING • se only and exclusively Lamborghini Caloreclima air intake/flue gas exhaust kits. - 0...
Page 29
Remove the air intake closing cap. Fit the two 80Ø flanged stub pipes with relative seals. If necessary, fit the baffle below the air intake stub pipe as shown in the figure. WARNING • Use only and exclusively Lamborghini Caloreclima air intake/flue gas exhaust kits. - 1...
Page 30
80Ø 90° male-female elbow Condensate trap 80Ø wind-resistant terminal for combustion products 80Ø air intake protection terminal 80/125 roof vent + TEE reducer for separate ducts WARNINGS • Use only and exclusively Lamborghini Caloreclima air intake/flue gas exhaust kits. - 2...
INSTALLATION ELECTRICAL CONNECTIONS The boiler must be connected to a 230V - 50Hz single-phase + earth power supply respecting the LINE-NEUTRAL polarity. The connection must be made using a bipolar magnetothermal switch with contact opening of at least 3.5 mm. During installation or if the power cable is replaced, provide for an earth cable 2 m longer than the other cables.
Page 32
INSTALLATION - Open the instrument panel - To remove the instrument panel lid remove the screws (2) - ...
INSTALLATION TURNING OFF EXTENDED PERIODS OF INACTIVITY If the boiler is to remain inactive for a long period of time, close the gas cock and cut the power to the boiler. TEMPORARY TURNING ON/OFF This can be achieved in one of the following two ways: - From the ambient thermostat.
INSTALLATION CHECKS AND ADJUSTMENTS ALMA 24 MBS W TOP DESCRIPTION G20 (natural gas) G30 (LPG) G31 (LPG) Nominal supply pressure 28 - 30 mbar maximum 11,3 25,4 mbar Pressure at nozzles minimum mbar Flow rate 0,78 Burner nozzles 1,25 0,77 0,77 Ø mm Gas baffle Ø mm P.C.I.
Page 35
INSTALLATION ALMA 28 MBS W TOP DESCRIPTION G20 (natural gas) G30 (LPG) G31 (LPG) Nominal supply pressure 28 - 30 mbar maximum 13,5 28,3 36,2 mbar Pressure at nozzles minimum mbar Flow rate Burner nozzles 1,25 0,77 0,77 Ø mm Gas baffle Ø mm P.C.I. (*) 8127 29000 22000 kcal/m...
Page 36
INSTALLATION ALMA 32 MBS W TOP DESCRIPTION G20 (natural gas) G30 (LPG) G31 (LPG) Nominal supply pressure 28 - 30 mbar maximum 12,5 27,5 35,2 mbar Pressure at nozzles minimum mbar Flow rate 3,74 1,03 1,35 Burner nozzles 1,35 0,82 0,82 Ø mm Gas baffle Ø mm P.C.I.
Page 37
INSTALLATION CHECKING COMBUSTION AND EFFICIENCY OF THE AIR PRESSURE SWITCH To access the flue gas analysis flange operate as follows: - Undo the screw (A) and remove the rubber cap (B): P1 = flue gas port; P2 = air port. Checking the efficiency of the air pressure switch - Loosen the two screws inside the pressure outlets (C) using a screwdriver. - Connect the two pressure outlet couplings to a pressure gauge by means of rubber hoses.
INSTALLATION OPERATION WITH DIFFERENT TYPES OF GAS The boiler is set up and adjusted at the factory to operate with G20 or G30/G31 as indicated on the technical data plate and the packaging. Should the boiler need to be used with a gas different from that for which it was set up at the factory, a specific kit must be installed to be ordered separately.
Page 39
INSTALLATION Adjusting the minimum pressure The gas pressure at the burner must be checked through the pressure outlet positioned on the gas valve outlet pipe using a water pressure gauge or a micro pressure gauge - Remove the protection cover (G). - Disconnect the power cable (12V) from the modulating coil. - Adjust the minimum pressure to the value indicated in the table below, screwing down (to increase) or unscrewing (to decrease) the adjusting screw (I).
MAINTENANCE MAINTENANCE In order to assure that the boiler remains functional and efficient within the limits laid down by current legislation and/or regulations, the boiler must be subjected to regular inspection. The frequency of inspection depends on the installation and utilisation conditions, however an annual inspection by per- sons authorised by Lamborghini Service is recommended.
Page 41
MAINTENANCE TROUBLESHOOTING Fault Cause Remedy Failed ignition - No gas - Check that the gas flow to the boiler is regular and that the air has been bled from the pipes - Detection or ignition electrode - Check the electrode wiring and malfunction that the electrodes are positio- ned properly and do not have...
Page 42
BRUCIATORI CALDAIE MURALI E TERRA A GAS GRUPPI TERMICI IN GHISA E IN ACCIAIO GENERATORI DI ARIA CALDA TRATTAMENTO ACQUA CONDIZIONAMENTO Le illustrazioni e i dati riportati sono indicativi e non impegnano. La LAMBORGHINI si riserva il diritto di apportare senza obbligo di preavviso tutte le modifiche che ritiene più...
Page 43
CALDAIA MURALE A GAS CON BOLLITORE AD ACCUMULO - ALTO RENDIMENTO - MODULANTE WALL-MOUNTED GAS BOILER WITH STORAGE WATER HEATER - HIGH EFFICIENCY - MODULATING CALDERA MURAL DE GAS CON INTERCAMBIADOR DE ACUMULACIÓN - ALTO RENDIMIENTO - MODULANTE 24 MBS W TOP 28 MBS W TOP 32 MBS W TOP LIBRETTO UTENTE...
Page 44
... on your excellent choice. Thank you for choosing our products. LAMBORGHINI CALORECLIMA is daily committed to seeking innovative technical solutions to satisfy every need. Constant presence of our products on the Italian and international markets is assured by a widespread network of Agents and Dealers assisted by “LAMBORGHINI SERVICE”...
Page 45
CONTENTS CONTENTS GENERAL SAFETY WARNINGS AND RULES Page 26 DESCRIPTION “ OPTIONAL ACCESSORIES “ TECHNICAL DATA “ SANITARY HOT WATER PERFORMANCE “ IDENTIFICATION “ CONTROL PANEL “ DISPLAY “ PARAMETER PROGRAMMING “ DESCRIPTION OF OPERATION AND FUNCTIONS “ MAINTENANCE “ - 2...
USER MANUAL SAFETY WARNINGS AND RULES • The instruction manuals provided form an integral part of the boiler and consequently must be carefully kept and must ALWAYS accompany the boiler, even in the case of transfer to another owner or user or transfer to another system. In the event of damage or loss, request another copy from your local Technical Service.
USER MANUAL DESCRIPTION The boilers operate fully automatically and the gas flow is controlled by an electronic control unit with the following cha- racteristics: - continuous modulation on both circuits - possibility of adjusting the heat output - possibility of adjusting slow ignition. The models are equipped with: - no-water pressure switch - full safety thermostat...
USER MANUAL TECHNICAL DATA DESCRIPTION ALMA 24 MBS W TOP Fuel Gas supply pressure (nominal) 28-30 mbar Boiler category II2H3+ Type of boiler B22 - C12 - C32 - C42 - C52 - C62 - C82 maximum Nominal heating power (Qn) minimum 12,1 maximum 24,36 Useful nominal output (Pn) minimum...
Page 49
USER MANUAL DESCRIPTION ALMA 28 MBS W TOP Fuel Gas supply pressure (nominal) 28-30 mbar Boiler category II2H3+ Type of boiler B22 - C12 - C32 - C42 - C52 - C62 - C82 maximum 30.4 Nominal heating power (Qn) minimum 14.2 maximum 28.45 Useful nominal output (Pn) minimum 12.6...
Page 50
USER MANUAL DESCRIPTION ALMA 32 MBS W TOP Fuel Gas supply pressure (nominal) 28-30 mbar Boiler category II2H3+ Type of boiler B22 - C12 - C32 - C42 - C52 - C62 - C82 maximum 34.5 Nominal heating power (Qn) minimum maximum 32.4 Useful nominal output (Pn) minimum 12.19 Max/min useful efficiency at Pn...
USER MANUAL IDENTIFICATION The ALMA boiler is identifiable by the labels on the packaging and the TECHNICAL DATA PLATE found inside the boiler as shown in the figure. WARNING • Tampering with, removing, missing identification plates or anything else that does not allow certain identification of the product makes any installation and maintenance operation difficult.
USER MANUAL CONTROL PANEL The ALMA boilers are equipped with the instruments shown below. Boiler status display P1 Boiler function selection button (Summer/Winter - ON/OFF) P2 Cyclic function selection P3 Heating temperature increase button P4 Heating temperature decrease button P5 Sanitary water temperature increase button P6 Sanitary water temperature decrease button The display shows 3 digits and some symbols that indicate the boiler operating mode.
USER MANUAL DISPLAY BUTTON FUNCTION SyMBOL Pressing the button for 3 seconds the following functions are displayed: Summer Summer ----> Winter Holding the button pressed down for 3 seconds the boiler switches off. Winter Pressing the button the following information is cyclically displayed: flashing Sanitary water temperature Heating temperature...
USER MANUAL PARAMETER PROGRAMMING Simultaneously press the buttons P2 and P3 for 10s to access the programming menu where the left digit indicates the parameter number, and the centre and right digits the parameter value. When the programming menu has been accessed, the left digit will blink; use the P3 and P4 buttons to change the para- meter number, and the P5 and P6 buttons to change the value which will immediately be stored.
USER MANUAL WARNINGS For each operating mode one or more symbols appear on the LCD display. In the event of a fault, the display will show a code whose meaning is summarised in the following table: Fault Code Failed ignition lock Safety thermostat intervention lock No water Air pressure switch (MCS)/flue gas thermostat (MC)
Page 56
USER MANUAL HEATING PUMP ANTI-LOCKING FUNCTION An anti-locking function activates the circulator for 30 seconds every 24 hours of inactivity. Following a power failure, the first anti-locking intervention occurs after 1 hour of inactivity. The function is active even when operation is locked and the selector is set to OFF.
Page 57
USER MANUAL FAN AND AIR FLOW CHECK (MBS MODELS) If an ignition request is received, the system checks for the absence of air flow (contact open) of the flue gas pressure switch, and if the test is passed the fan is activated. When air flow is detected (contact closed) the ignition sequence is started.
Page 58
USER MANUAL HEATING MODE WITH EXTERNAL SENSOR (OPTIONAL) Operation is the same as in normal heating mode with the difference that the delivery temperature is calculated in relation to the external temperature read by the sensor and the K factor. The K factor is set with the P3 and P4 buttons. HEATING TEMPERATURE INCREASE BUTTON HEATING TEMPERATURE DECREASE BUTTON External temperature (°C)
Page 59
USER MANUAL OPERATION WITH REMOTE CONTROL (OPTIONAL) The boiler can be operated with a RC03.54 remote control. The RC03.54 remote control is an intelligent hourly programmer complete with ambient sensor suitable for adjustment and control of wall-mounted gas boilers for heating and production of sanitary hot water mainly for installation in residential buildings.
Page 60
USER MANUAL Adjusting the minimum pressure The gas pressure at the burner must be checked through the pressure outlet positioned on the gas valve outlet pipe using a water pressure gauge or a micro pressure gauge - Remove the protection cover (G). - Disconnect the power cable (12V) from the modulating coil. - Adjust the minimum pressure to the value indicated in the table below, screwing down (to increase) or unscrewing (to decrease) the adjusting screw (I).
USER MANUAL MAINTENANCE In order to assure that the boiler remains functional and efficient within the limits laid down by current legislation and/or regulations, the boiler must be subjected to regular inspection. The frequency of inspection depends on the installation and utilisation conditions, however an annual inspection by per- sons authorised by Lamborghini Service is recommended.
Page 62
USER MANUAL TROUBLESHOOTING Fault Cause Remedy Failed ignition - No gas - Check that the gas flow to the boiler is regular and that the air has been bled from the pipes - Detection or ignition electrode - Check the electrode wiring and malfunction that the electrodes are positio- ned properly and do not have...
Page 63
BRUCIATORI CALDAIE MURALI E TERRA A GAS GRUPPI TERMICI IN GHISA E IN ACCIAIO GENERATORI DI ARIA CALDA TRATTAMENTO ACQUA CONDIZIONAMENTO Le illustrazioni e i dati riportati sono indicativi e non impegnano. La LAMBORGHINI si riserva il diritto di apportare senza obbligo di preavviso tutte le modifiche che ritiene più...