Fault Diagnosis
WARNING - Before undertaking maintenance operations or adjustments switch off
machine and unplug from the electricity supply
Problem
No electrical power
Switch is turned on. Intermittent
power to motor(s).
Vacuum motor on
Little or no vacuum on wand
head.
Not enough vacuum power at
the machine.
Motor running and no vacuum.
No exhaust from the blowport
Premature closing of ball type
shutoff.
Ball type shutoff failing to
release after ball recovery tank
is drained.
Foam/dirty solution - coming out
of vacuum exhaust port.
7
Bottles
Part No.
per case
10
HMC01005
10
HMC01010
4
HMC01050
10
HM003005
Reason

ELECTRICAL SYSTEM

1. Defective power cord.
2. Fuse blown.
1. Faulty electrical cable.
2. Defective switches.
3. Loose terminal

VACUUM SYSTEM

1. Drain valve open
2. Defective vacuum hose
3. Vacuum disconnected
1. Damaged recovery tank
lid.
2. Lint clogging ball - type
shutoff screen
3. Vacuum hose connection
between stand pipe and
vacuum motor.
4. Vacuum motor exhaust
blocked.
1. Faulty vacuum motor.
2. Float valve blocked.
1. Dirty or clogged shut off
filter screen.
2. Ball coated with detergent
or other foreign material.
3. Screen slightly out of
round.
1. Foam from carpet by
passing water shutoff.
2. Elbow in vacuum tank is
not positioned correctly
Description
The quality way to beautify carpets and
upholstery. Formulation lifts dirt and
stains out of your carpets and helps
prevent re-soiling. Leaves carpets and
upholstery soft and fresh.
Formulated to help remove stubborn
stains from carpet and upholstery
Remedy
1. Replace
2. Replace fuse. Unplug any
equipment using the same circuit.
1. Replace cable
2. Contact service agent
3. Contact service agent.
1. Close drain valve. Recovery tank
lid must be closed
2. Repair or replace hose. Remove
kinks in vacuum hose.
3. Open machine, connect vacuum
hose to recovery tank.
1. Replace
2. Remove screen. Clean out fibres
and accumulated dirt.
3. Check for leaks around clamps
and cuffs (tighten). Replace
damaged hose(s).
4. Check air flow by removing hose
from machine and feel the exhaust
under the machine. Remove
obstruction.
1. Replace.
2. Clean water shutoff screen.
1. Remove and clean screen.
2. Remove and rinse ball with clean
water.
3. Bend screen by squeezing slightly
by hand until there is an obvious
space between ball and inside of
screen.
1. Use additional defoamer.
2. The elbow should be pointed
directly at the side wall of the tank
away from the ball type shutoff.