Contents Page 1 General Information ................5 Important safety advice ............. 5 Guidelines for the operator ............5 Transporting the machine ............5 Electrical connection ..............5 2 Preparing for use ................6 Fitting the handle ............... 6 Fitting the dust bag ..............6 3 Controls .....................
If in doubt contact the supplier of your machine. should not be used or stored outdoors in wet These instructions are valid for the following models. conditions. Orbis – OB45200, OB45400, OB452/400 1.3 Transporting the machine 1.1 Important Safety Advice CAUTION - THIS MACHINE IS HEAVY...
Connection point for vacuum unit lead. 2 Preparing for use Drive plate 2.1 Fitting the handle Attachment point for brush or drive disc and pad. 1. Carefully remove the machine base and handle Cable winder from their respective packaging. 2. Check that the following items are present with Used to hold supply cord in place on handle when the base and remove them from their transit machine is not in use.
• Once the machine has started the interlock buttons should be released. 4.5 Fitting the solution tank • To stop the machine release both switch triggers. NOTE - The solution tank is supplied as an accessory item, complete with attachments and fitting instructions.
Store the machine in a dry indoor area only. Never store the machine with a pad fitted as this Truvox International Limited policy is one of continual causes distortion, and results in instability during product development and we reserve the right to alter operation.
9 Technical specification ∼ All models : 230-240V 50Hz, Class I construction. Enclosure to IPX4. Fitted with 15m supply cord type and 13A fused plug. 45cm Model 45cm 45cm 2/400 Pad diameter Pad pressure gm/cm² 27,5 Speed 190/380 Motor rating 1100 1100 1100...
11 Fault diagnosis The following simple checks may be performed by the operator. Trouble Reason Remedy Machine not working, neon indicator Lack of voltage/electrical supply. Check fuse *, supply cord, plug not lit. and socket outlet. Machine not working, neon indicator Switch interlock incorrectly Check operating procedure in lit.
Page 11
: floor cleaning machines Type : Orbis Model : OB45200, OB45400, OB452/400 Serial Number Year of Construction : 2000 has been manufactured using the following transposed harmonized European Standards and technical specifications. BS EN 50081-1, BS EN 55014-1 & 2, BS EN 60335-1 and...
Page 12
Truvox International Limited Third Avenue, Millbrook, Southampton, Hampshire SO15 0LE, England Tel: +44 (0) 23 8070 2200 Fax: +44 (0) 23 8070 5001 e-mail: truvox@truvox.com Web: www.truvox.com...