[ Power Supply Section ]
FLOW CHART NO.1
The power cannot be turned on.
Is the fuse (F601) normal?
Is the INV+35V line voltage normal?
FLOW CHART NO.2
The fuse blows out.
FLOW CHART NO.3
When the output voltage fluctuates.
FLOW CHART NO.4
When buzz sound can be heard in the vicinity of power circuit.
FLOW CHART NO.5
INV+35V is not output.

TROUBLESHOOTING

Yes
Yes
Yes
Yes
Yes
No
See FLOW CHART No.2 <The fuse blows out.>
No
Check if there is any leak or short-circuiting on the
primary circuit component, and service it if defective.
(C605, C606, D601, D602, D603, D604, Q601,
No
Q602, T601)
No
Check IC601, D652, Q631 and their periphery
circuit, and service it if defective.
No
Check C638, D634, D636, D639 and their periphery
circuit, and service it if defective.