FLOW CHART NO.1
The power cannot be turned on.
Is the fuse (F601) normal?
Is the AL+33V line voltage normal?
FLOW CHART NO.2
The fuse blows out.
FLOW CHART NO.3
When the output voltage fluctuates.
FLOW CHART NO.4
When buzz sound can be heard in the vicinity of power circuit.
TROUBLESHOOTING
Yes
Yes
Yes
Yes
No
See FLOW CHART No.2 <The fuse blows out.>
No
Check if there is any leak or short-circuiting on the
primary circuit component, and service it if defective.
(IC605, Q601, Q602, D602, D604, D605, D607,
No
T601, R602)
No
Check IC605, Q603, D615, D620, D623, D628 and
their periphery, and service it if defective.
8-1
A0CN0TR