1.4.4

Securing the Device with Clamps

You require 6 clamps in order to mount the device with a 12"/15" display. A device with a 19"
display must be mounted with 8 clamps. The required number of clamps is include in your
Panel PC delivery package.
Required tool for fasting the clamps: 2.5 mm hexagonal spanner
Figure 1-3

Rack Mounting

Steps for fastening the device with clamps
1
2
3
Swivel Arm Mounting
Steps for fastening the device with clamps
1
2
3

Control Cabinet Installation

Steps for fastening the device with clamps
1
2
3
SIMATIC Panel PC 677
Operating Instructions (Compact), Edition 07/2006, A5E00877730-01
Clamp assembly
Isolate the device from power supply.
Working from the front, insert the device into the 19" rack
Fasten the control unit in the rack from the rear using the clamps. Tighten the setscrews to a
torque of 0.4-0.5 Nm
Isolate the device from power supply.
Working from the front, place the device onto the swivel arm
Fasten the control unit on the swivel arm from the rear using the clamps. Tighten the setscrews
to a torque of 0.4-0.5 Nm
Isolate the device from power supply.
Working from the front, insert the device into the mounting cut-out
Secure the control unit in the mounting cut-out from behind with the clamps, as shown in the
mounting cut-out in the dimensions. Tighten the setscrews to a torque of 0.4-0.5 Nm