DTC P0112 (15), P0113 (15)

GENERAL

Intake Air Temperature (IAT) Sensor
See
Figure
2-46.The Electronic Control Module (ECM) supplies
and monitors a signal at terminal "14" of [11] to one side of the
IAT sensor. The other side of the IAT sensor is connected to
a common sensor ground, which is also connected to the ECM
terminal "27" of [11].
Refer to
Table
2-28. The IAT sensor is a thermistor device,
meaning that at a specific temperature, it will have a specific
resistance across its terminals. As this resistance varies, so
does the supplied voltage to terminal "14".
ed01492
Figure 2-45. IAT Sensor
At high temperatures, the resistance of the sensor is very
low. This effectively lowers the signal voltage on terminal
"14".
At low temperatures, the resistance is very high, allowing
the voltage to rise close to the supplied voltage of 5 volts.
The ECM monitors this voltage to compensate for various
operating conditions.
Table 2-27. Code Description
DTC
CHECK
ENGINE
LAMP CODE
P0112
15
P0113
15
2-54 2008 Buell XB Diagnostics: Engine Management
DESCRIPTION
Intake air temperature sensor
voltage low
Intake air temperature sensor
voltage high/open
Table 2-28. Intake Air Temperature Sensor Specifications
VOLTS
RESISTANCE
0.49
1086
0.68
1561
0.86
2077
1.13
2920
1.40
3889
2.25
8149
3.09
16,178
3.52
23,670
3.94
31,170
4.24
55,359
4.53
96,383
4.68
146,250
4.83
284,118
All voltage and resistance values are approximate (±20%).
DIAGNOSTICS
PART NUMBER
B-48115
BREAKOUT BOX
HD-41404-B
HARNESS CONNECTOR TEST KIT
Diagnostic Tips
An intermittent may be caused by a poor connection, rubbed
through wire insulation or a wire broken inside the insulation.
Check for the following conditions:
Poor connection. Inspect ECM harness connector for
backed out terminals, improper mating, broken locks
improperly formed or damaged terminals, poor terminal-
to-wire connection and damaged harness.
Perform
2.7 WIGGLE TEST
connectors and harness check out OK, check intake air
temperature reading while moving related connectors and
wiring harness. If the failure is induced, the IAT sensor
display will change.
Shifted sensor.The temperature-to-resistance values table
may be used to test the IAT sensor at various temperature
levels in order to evaluate the possibility of a shifted (out-
of-calibration) sensor which may result in driveability
problems.
Diagnostic Notes
Each reference number below correlates to a circled number
on the flow chart(s).
1.
Connect BREAKOUT BOX (Part No. B-48115) to EFI
harness
only
(leave
2.6 BREAKOUT
BOX.
2.17
TEMP °C
TEMP °F
125
257
113
235
100
212
90
194
80
176
60
140
40
104
30
86
20
68
10
50
0
32
-10
14
-20
-4
NOTE
TOOL NAME
to locate intermittents. If
ECM
disconnected).
See

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents