Air is leaking or
the crown punch
does not move
up or down
properly.
Edlund Company CROWN PUNCH CAN OPENER, Models 610M and 610
12
K. With a can seated in the guard ring, inspect the gap between the guard ring and the
top of the can seam. See "Setup and Operation", (page 6.)
L. Insure the large pneumatic cylinder is working properly.
M. Should a lid remain attached to the can after operating the crown punch, disconnect
the air supply. First check the spacing between can and guard ring for proper gap. If
this is acceptable, loosen the head of the crown punch with the "T bolts", set the
head so it is level with the can. Re-attach the air supply and open another can.
SERVICE SHOULD ONLY BE PERFORMED BY A QUALIFIED SERVICE
TECHNICIAN. Call our Technical Support Representatives at 1-800-772-2126.