POSITIVE PRESSURE VENTILATOR USER GUIDE This manual covers the description, cautions, operation, and maintenance of the Super Vac 720GC. Please take the time to read this manual before operating the ventilator. Save this guide for future reference. CONTENTS 1. BREAKAGE OR DAMAGE DURING SHIPMENT......................
POSITIVE PRESSURE VENTILATOR 1. Breakage or Damage During Shipment The transportation company is fully responsible for all shipping damage and will resolve problems promptly if you handle it correctly. Please read these instructions carefully. Examine the contents of all shipping cases. If you find any damage, call your transportation agent at once and have them make a description on the freight or express bill describing the damage and the number of pieces.
AMCA PPV Standard 240-95, for use in extreme conditions. This ventilator is designed for high powered air movement. Super Vac’s propeller produces a greater intake of air and eliminates turbulence at the tips. Each blade is dynamically balanced for high efficiency and long life.
Refer to the HONDA ENGINE Owner’s Manual for additional information showing locations of engine control features and positions. Use caution not to direct toxic fumes into confined spaces with the ventilator. Please refer to the Super Vac Training Manual for Smoke Ventilation for comprehensive instruction on effective ventilation practices.
POSITIVE PRESSURE VENTILATOR Starting the Engine 1. Move the fuel lever to the ON position. 2. If engine is cold, move choke lever to the CLOSED position. 3. Move throttle lever to 1/3 of the way toward the FAST position. 4.
POSITIVE PRESSURE VENTILATOR 6. Maintenance and Repair Maintenance should only be performed by experienced and trained personnel. Be sure the ventilator blade has come to a complete stop before performing any maintenance or repair. Disconnect spark plug wire from spark plug and keep it away from spark plug. The ventilator blade should be specially checked for build-up of material or dirt which may cause an imbalance.
POSITIVE PRESSURE VENTILATOR 7. Troubleshooting Common causes of engine overheating: • Insufficient unobstructed distance on exhaust side of ventilator. Please refer to the Super Vac Training Manual for Smoke Ventilation for recommended ventilator placement. • Incorrect octane fuel - too low octane...
POSITIVE PRESSURE VENTILATOR 8. Warranty Super Vacuum Manufacturing Company warrants that the equipment is free from defects in materials and workmanship when used and operated for a period of five years. The responsibility of Super Vacuum Manufacturing Company under this limited warranty is limited to the repair and replacement of any parts which are found defective and which are returned to Super Vacuum Manufacturing Company at 3842 Redman Dr, Fort Collins, CO 80524 with transportation charges prepaid (C.O.D.
POSITIVE PRESSURE VENTILATOR 9. Contact Information For parts or service information, contact: Super Vacuum Manufacturing Company, Inc. 3842 Redman Dr. Fort Collins, CO 80524 Phone: 800-525-5224 970-297-7100 Fax: 970-297-7099 Email : info@supervac.com Internet: www.supervac.com 720GC PPV User Guide Revised 9-2015...