PR 9106B Manual page 13

Hart transparent repeater
Table of Contents

Advertisement

current output:
Signal range ................................................ 3.5...23 mA
Load (max.) .................................................. 20 mA / 600 Ω / 12 VDC
Load stability ............................................... ≤ 0.01% of span / 100 Ω
Current limit ................................................. ≤ 28 mA
Passive 2-wire output installation:
Max. external 2-wire supply ........................ 26 VDC
Max. load resistance [Ω] ............................. (V
- 3.5) / 0.023 A
supply
Effect of external 2-wire supply
voltage variation .......................................... < 0.005% of span / V
*of span = normal measurement range 4...20 mA
Status relay output terminal 33-34:
Relay function.............................................. N.C.
Programmable low setpoint ........................ 0...29.9 mA
Programmable high setpoint ....................... 0...29.9 mA
Hysteresis for setpoints............................... 0.1 mA
Max. voltage ................................................ 110 VDC / 125 VAC
Max. current ................................................ 0.3 ADC / 0.5 AAC
Max. voltage - hazardous installation ......... 32 VDC / 32 VAC
Max. current - hazardous installation .......... 1 ADC / 0.5 AAC
9106 - Product Version 9106-002