PARRY P6BDO Installation Instructions Manual page 6

Table of Contents

Advertisement

TELEPHONE:
FAX:
MODEL P6BDO TECHNICAL DETAILS
FLOW TEST SEQU 2
HOB BURNER
PRESSURE
INJECTOR
GAS RATE
HEAT INPUT
OVEN
INJECTOR
GAS RATE MAX
GAS RATE MIN
HEAT INPUT MAX
HEAT INPUT MIN
TOTAL HEAT INPUT NATURAL GAS
TOTAL HEAT INPUT PROPANE
LOW RATE ADJUSTER SCREW
OVEN BYPASS ADJUSTER SCREW
LOW RATE ADJUSTER SCREW
OVEN BYPASS ADJUSTER SCREW
Gas connections ½ B.S.P.T. at left hand rear of appliance incorporating pressure test
point.
Oven size 750mm wide x 600 deep x 475mm high = volume 0.2M3 (7.4ft3)
Appliance Total Weight 135 kg.
L.P.G. Conversion kit is available for this appliance and should be fitted by a qualified
engineer if required. (See L.P.G. Conversion instructions)
On conversion to G25 the oven burner is fitted with an Air Restricter. This is available
from PARRY Group Ltd.
TEST 3 HOB FLOW RATE HIGH =
TEST 4 HOB FLOW RATE LOW =
TEST 5 OVEN FLOW RATE
TESTS 3 AND 4 ALO APPLY TO ALL PARAGON AND ALPHA HOB UNITS.
L.P.G. SEQU 6 HOB HIGH .190 LOW .034 OVEN .290
SERVICE (44) 01332 875665
SERVICE (44) 01332 875536
NAT
G20
G31
20mbar
37mbar
1.75mm
1.07mm
0.530m3/hr
0.20m/2hr
5.77KW
4.84KW
2 x 1.5mm
2 x 0.9mm
0.72m3/hr
0.29m3/hr
0.14m3/hr
0.12m3/hr
7 KW
7.00KW
1.3 KW
3.0KW
=
INSTRUCTION REF: IN151
ISSUE No.
DATE 10.02.04
Page 6 of 19
G25
25mbar
1.75mm
0.65m3/hr
5.87KW
2 x 1.50mm
0.77mm3/hr
0.12mm3/hr
6.5KW
1.4KW
G20/25
41.62KW
G31
36.04KW
G20/25
SIZE 84
G20/25
SIZE 95
G30/31
SIZE 50
G30/31
SIZE 55
.530 M³/HR
.110 M³/HR
.720 M³/HR
2

Advertisement