PARRY PGG7 Product Instructions

PARRY PGG7 Product Instructions

Gas griddle
Hide thumbs Also See for PGG7:

Advertisement

Quick Links

Instruction Manual
PGG7/PGG7P
Parry Gas Griddle

Advertisement

Table of Contents
loading

Summary of Contents for PARRY PGG7

  • Page 1 Instruction Manual PGG7/PGG7P Parry Gas Griddle...
  • Page 3: Table Of Contents

    Parts List ............................16 Replacement Parts ......................... 17 Warranty Information........................ 18-19 Disposal & Recycling ........................20 Parry Catering Equipment (Midlands) Ltd, Town End Road, Draycott, Derby, DE72 3PT. Sales Tel: 01332 875544 Fax: 01332 874455 Parry-British Built for Purpose IN103-8...
  • Page 4: Product Overview

    Product Overview The Parry PGG7 gas countertop double griddle is powerful, reliable and user-friendly, making it an essential addition to any busy commercial kitchen. The polished steel plate provides outstanding heat distribution and retention, cooking bacon, eggs, onions and burgers to perfection. The adjustable gas valve controls the temperature from high to low, whilst the removable waste drawers collect any residue fat.
  • Page 5: Safety Instructions

    To avoid scratching the highly polished exterior surface of this equipment whilst in transit, the protective film on the exterior surfaces has NOT been removed. It is IMPORTANT that this protective film is peeled off before the equipment is used. Parry-British Built for Purpose IN103-8...
  • Page 6: Installation Instructions

    It is recommended that the appliance be sited below a ventilating hood preferably of the extractor type incorporating a grease filter. Appliances are designed to be installed and fitted on a Parry stand for stability. If they are fitted on any other surface they should be suitably secured.
  • Page 7 All units should have a restraining cable fitted preventing the unit from being pulled away from the wall and causing the gas hose to become disconnected accidentally. Parry-British Built for Purpose IN103-8...
  • Page 8: Operating Instructions

    To remove any residue, use a scraper several times a day after cooking. Scaling will result if this is not done. Empty the fat drawer and clean every day. Parry-British Built for Purpose IN103-8...
  • Page 9: Cleaning Instructions

    Ensure the appliance is isolated from the power supply before installing, cleaning or maintaining the appliance. Parry Catering provides a complete after-sales service by offering the sales of spare parts directly to customers. Buying spares straight from the manufacturer allows customer to experience exceptional value and speedy delivery on all spare parts.
  • Page 10 Thoroughly clean the plate and fat chute, and drawer. Replace the thermostat phial to its correct position and fasten the plate down to the body by tightening the nut. Refit fascia panel with the 2 screws and re-attach the control knobs. Parry-British Built for Purpose IN103-8...
  • Page 11: Replacement Faulty Components

    Refit the saddle bracket and tighten the two screws. Reconnect gas feed to injector and gas cock and tighten Refit pilot supply Refit thermocouple and tighten do not over tighten Parry-British Built for Purpose IN103-8...
  • Page 12: Fault Finding

    If this does not work, contact Ensure to hold the control knob in Unit will not stay lit engineer to replace faulty for 10 seconds whilst lighting. parts. Parry-British Built for Purpose IN103-8...
  • Page 13: Conversion Procedure

    This must only be done by a qualified Gas Safe Engineer, and as this setting has been factory sealed. Any alterations must be resealed. Model Injector Code PGG7 Propane G31 @ 37mbar 14.8” W.G. INJECT099 PGG7 Nat Gas G20 @ 20mbar 8” W.G. INJECT150 Parry-British Built for Purpose IN103-8...
  • Page 14: Technical Data

    W.G. 7.098 KW = 24221Btu/h PROPANE G31 37mb/14.8” W.G. 5.127 KW = 17494Btu/h Gas Rate M³/HR FT³/HR LB/HR KG/HR NATURAL G20 0.736 25.988 PROPANE G31 0.220 7.768 0.888 0.404 AIR FLOW RATE 259.88 COMBUSTION 20m3/hr Parry-British Built for Purpose IN103-8...
  • Page 15 Gas Rate M³/HR FT³/HR LB/HR KG/HR NATURAL G20 0.320 11.275 PROPANE G31 0.145 5.124 0.611 0.277 Model Injector Code PGG7 Propane G31 @ 37mbar 14.8” W.G. INJECT099 PGG7 Nat Gas G20 @ 20mbar 8” W.G. INJECT150 Parry-British Built for Purpose IN103-8...
  • Page 16: Service Information

    This appliance should be routinely serviced to prolong its lifetime. Parry recommends that the appliance is serviced every 12 months by a Parry authorised engineer. Failure to service your product within the initial 12-month warranty period will cause the 24-month warranty to become void.
  • Page 17: Exploded View

    Exploded View Parry-British Built for Purpose IN103-8...
  • Page 18: Parts List

    INJECT099 (LPG) Injector 8mm Olive Part of above Injector Compression nut Part of above Injector Lock Nut Part of above Aerator LCB00017 Bracket for Thermocouple and MBETCASSY Electrode Electrode Part of above Thermocouple Part of above Parry-British Built for Purpose IN103-8...
  • Page 19: Replacement Parts

    Part Number Description PGG7 NATURAL CONVERSION KIT CONSISTS OF: INJECT150 NATURAL INJECTOR-PGG7, (14) SET OF LABELS IN103-4 INSTRUCTION PACK LPG CONVERSION KIT CONSISTS OF: INJECT099 LPG INJECTOR- PGG7, (14) SET OF LABELS IN103-4 INSTRUCTION PACK Parry-British Built for Purpose IN103-8...
  • Page 20: Warranty Information

    Parry and not the sale or installation date of the equipment. Please ensure you have referred to the manufacturer’s instruction before placing a warranty call.
  • Page 21: Disposal & Recycling

    Disposal & Recycling The packaging should be disposed of in accordance with the regulations in force. Parry-British Built for Purpose IN103-8...