Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
HP Manuals
Measuring Instruments
3400A
Operating and service manual
Specifications; Product View - HP 3400A Operating And Service Manual
Rms voltmeter
Hide thumbs
Also See for 3400A
:
Operating manual
(214 pages)
,
Operating and service manual
(81 pages)
,
Operating and service manual
(64 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
Table Of Contents
65
page
of
65
Go
/
65
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Section
I
Model 3400A
U
M00»
RMSVOLTMETtR
/->.
oe
-10
VOLTS
.3
RANGE
VOLTS
1
OB
-M
.1
v
/
S
10
-M
03
^J
L-
io
20
-40
.01
-^
m
30
JO
-so
.003 '
W
100
«0
-60
.001
—
—
300
so
40
^*
Table
1-1.
Model 3400A
Specifications
VOLTAGE
RANGE:
1
mV
to
300
V
full
scale, 12
ranges.
DB
RANGE:
-72
to
+52
dBm
(0
dBm
1
mW
in
600
n).
FREQUENCY
RANGE:
10
Hz
to
10
MHz.
RESPONSE:
Responds
to
rms
value
(heating value)
of input signal.
METER
ACCURACY:
%
of
Full
Scale
(20°C
to
30°C)*
10
Hz
50
Hz
1MHz
2
MHz
3
MHz
10
MHz
±5%
±1%
±2%
±3%
±5%
AC
-to
-DC
CONVERTER
ACCURACY:
%
of
Full
Scale
(20°C
to
30°C)*
10
Hz
50
Hz
1MHz
2
MHz
3
MHz
10
MHz
±5%
±0.
75%
±2%
±3%
±5%
OUTPUT:
Negative
1
V
dc
into
open
circuit for
full-scale deflection,
proportional
to
meter
deflection;
1
mA
maximum;
nominal source
impedance
lOOOfi.
OUTPUT
NOISE:
<
1
mV
RMS.
CREST FACTOR:
(ratio
of
peak-to-rms
ampli-
tude
of input signal): 10:1
at full
scale (except
where
limited
by
maximum
input),
inversely
proportional
to
meter
deflection
(e. g.
,
20:1
at
half -scale,
100:1
at
tenth-scale).
INPUT IMPEDANCE:
0.
001
V
to
0.
3
V
range;
10
Mfi
shunted by <50 pF:
1.
V
to
300
V
range;
10
MS2 shunted by <20
pF.
AC
-coupled
input.
AC OVERLOAD:
30
dB
above
full
scale or 800
V
peak,
whichever
is
less,
on each range.
MAXIMUM DC
INPUT:
600
V
on any
range.
RESPONSE
TIME: For
a step function, <
5
seconds
to
respond
to final value.
POWER:
115
or 230
V
±10%,
48
to
440 Hz.
approximately
7
watts.
WEIGHT:
Net
7
1/4
lbs.
(3,
3kg);
shipping 10
lbs.
(5
kg).
OVERALL
DIMENSIONS:
6
1/2"
high;
5
1/8" wide;
11
11/16" deep.
•
Temperature
Coefficient:
±0. 1% over range
of
Qoc
to
20°C
and
30°C
to
55°C.
It
1-0
Table of
Contents
Previous
Page
Next
Page
1
...
5
6
7
8
9
10
11
12
Show Quick Links
Quick Links:
Specifications
Adjustment and Calibration Procedures
Circuit Diagrams
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Troubleshooting
Troubleshooting procedures
23
Troubleshooting Tree
25
Related Manuals for HP 3400A
Synthesizer HP HP 3325B Operating Manual
Synthesizer/function generator operating manual (214 pages)
Measuring Instruments HP 3400A Operating And Service Manual
Rms voltmeter (81 pages)
Measuring Instruments HP 3400A Operating And Service Manual
Rms voltmeter (64 pages)
Measuring Instruments HP 3458A Technical Manual
Digital voltmeter (43 pages)
Measuring Instruments HP 3456A Operating And Service Manual
Digital voltmeter (385 pages)
Measuring Instruments HP 3456A Operating And Service Manual
Digital voltmeter (315 pages)
Measuring Instruments HP 3455A Operating And Service Manual
Digital voltmeter (249 pages)
Measuring Instruments HP 3455A Operating And Service Manual
Digital voltmeter (219 pages)
Measuring Instruments hp 3406A Operating And Service Manual
Broadband sampling voltmeter (88 pages)
Measuring Instruments HP 3437A Operating And Service Manual
System voltmeter (15 pages)
Measuring Instruments HP 3400B User's And Service Manual
Rms voltmeter (77 pages)
Measuring Instruments HP 37717C Operating Manual
Communications performance analyzer, pdh / dsn (80 pages)
Measuring Instruments HP 37718A Installation And Verification Manual
(202 pages)
Measuring Instruments HP 3562A Service Manual
Dynamic signal analyzer (570 pages)
Measuring Instruments HP 3529A Quick Start Manual
Magnetometer probe (6 pages)
Measuring Instruments HP 3048A Operating Manual
Phase noise measurement system (214 pages)
Related Content for HP 3400A
545A Specifications
HP 545A
435B Specifications
HP 435B
EPM E4418A Specifications
HP EPM E4418A
547A Specifications
HP 547A
3455A Specifications
HP 3455A
11941A Specifications
HP 11941A
4262A Specifications
HP 4262A
3580A Specifications
HP 3580A
7044B Specifications
HP 7044B
3400A Specifications
HP 3400A
8555A Input Specifications
HP 8555A
E4419B Specifications
HP E4419B
1660C Series Specifications (Logic Analyzer)
HP 1660C Series
1660 Series Specifications (Logic Analyzer)
HP 1660 Series
4262A Specifications
HP 4262A
Q METER 4342A Specifications
HP Q METER 4342A
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL