This is a copy of the label that accompanies each
Regency Hearth Heater. We have printed a
copy of the contents here for your review.
SAFETY LABEL FOR H2104M
LISTED FACTORY BUILT FIREPLACE ACCESSORY HEARTH STOVE
CERTIFIED FOR USE IN CANADA AND U.S.A.
MODEL: H2100M
TESTED TO: ULC S628-M93 / UL 1482-1998 REPORT NO. 6255 (JULY 1991)
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. INSTALL AND USE ONLY IN MASONRY FIREPLACE
OR FACTORY BUILT FIREPLACE.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURED FROM INSERT BODY)
ADJACENT SIDEWALL
A) 10 in / 255 mm
MANTEL
B) 25 in / 635 mm
TOP FACING
C) 14 in / 355 mm
SIDE FACING
D) 8.5 in/ 216mm
HEARTH EXTENSION (DEPTH)
E) 18 in / 455 mm
HEARTH EXTENSION (ELEVATION)
F) 1.5 in/ 38 mm
HEARTH EXTENSION (WIDTH)
G) 6 in / 150 mm
DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE
OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED DOOR CLOSED, OPEN TO FEED FIRE ONLY.
REPLACE GLASS ONLY WITH CERAMIC GLASS (5 MM).
INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY.
DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.
2015 2016
2017
DATE OF MANUFACTURE
MADE IN CANADA
Part #: 908-389c
SAFETY LABEL FOR I3104L
Size: 10.06" W x 3.27" H (fi le at 100%)
Colour: Black on grey, except for what is highlighted in yellow is red.
Nov. 25/14: Updated ETL Logo
Jan. 22/14: Updated yrs of manufacture
LISTED FACTORY BUILT FIREPLACE INSERT
Apr. 4/11:updated yrs. of manufacture / added 5.5" stainless liner
CERTIFIED FOR USE IN CANADA AND U.S.A.
Mar. 15/10: updated yrs. of manufacture.
MODEL: I3100L
TESTED TO:
Jan. 2/08: updated yrs. of manufacture.
ULC S628-M93 / UL 1482-1998 / ULC S627-00 / UL 737-2000
Install and use only in accordance with the manufacturer's installation and operating instructions. Install and use only in masonry
fi replace or factory built fi replace. Contact local building or fi re offi cials about restrictions and installation inspection in your area.
Minimum Clearances to Combustibles
(Measured from insert body)
ADJACENT SIDEWALL A) 13"(330mm)
MANTLE
B) 19"(480 mm)
TOP FACING
C) 18"(455 mm)
SIDE FACING
D) 6.5"(165mm)
COMPONENTS REQUIRED FOR INSTALLATION: 5.5" (140mm) or 6" (152mm) STAINLESS STEEL LINER.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS, SCREEN DOOR
DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO
NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED DOOR
CLOSED, OPEN TO FEED FIRE ONLY. REPLACE GLASS ONLY WITH CERAMIC GLASS (5mm). INSPECT AND CLEAN
CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. DO
NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.
DATE OF MANUFACTURE
2015
908-343c
Part #: 908-343b
Size: 9.17" W x 3.97" H (File at 100%)
Color: Everything printed black on grey except what is indicated as being printed in red.
Dec. 16/14: Rev. C Updated ETL logo and manufacture dates
Sept. 26/13:updated yrs. of manufacture.
Apr. 7/11 Added. 5.5" stainless liner size
NOTE: Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
(Duplicate Serial #)
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5 IN / 38 MM
ABOVE AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST
BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING (E) 18 IN / 455
MM TO FRONT AND (G) 6 IN / 150 MM TO SIDES.
COMPONENTS REQUIRED FOR INSTALLATION MUST HAVE EITHER A 5.5"
(140mm) or 6" (150MM) STAINLESS STEEL LINER.
JAN
FEB
MAR APR
MAY JUN
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5" (38mm)
ABOVE AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR
MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING
(E) 16" (405mm) TO FRONT AND (G) 8" (205mm) TO SIDES FROM FUEL
DOOR.
2016
2017
JAN
FEB
MAR APR
103
DO NOT REMOVE THIS LABEL
103
MANUFACTURED BY:
FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST. DELTA, BC V4G 1H4
908-389c
JUL
AUG SEPT OCT
NOV DEC
DO NOT REMOVE THIS LABEL
106
REPORT NO. 632-323500
Manufactured by:
FPI FIREPLACE PRODUCTS
INTERNATIONAL LTD.
6988 Venture Street
Delta, BC V4G 1H4
MADE IN CANADA
MAY
JUN
JUL
AUG
SEPT OCT
safety decal
CAUTION
HOT WHILE IN OPERATION
DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE
SKIN BURNS. READ ABOVE
INSTRUCTIONS.
UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY CERTIFIED TO
COMPLY WITH JULY 1990, PARTICULATE
EMISSION STANDARDS.
CAUTION
(MAR.1994)
HOT WHILE IN OPERATION
DO NOT TOUCH. KEEP
CHILDREN, CLOTHING
AND FURNITURE AWAY.
CONTACT MAY CAUSE
SKIN BURNS. READ ABOVE
INSTRUCTIONS.
UNITED STATES
ENVIRONMENTAL PROTECTION
AGENCY CERTIFIED TO COMPLY
NOV
DEC
WITH JULY 1990, PARTICULATE
EMISSION STANDARDS.
H2104 / I3104 Wood Insert |
|