LAYOUT:

FRONT
3
2
1
4
1 - GREEN LED
: power on.
2 - YELLOW LED
: printing cycle.
3 - ORANGE LED
: error signal (see section 7).
4 - BLUE button: opening/closing carriage.
5 - Carriage.
6 - Lid.
7 - USB socket (type B).
8 - Power supply socket.
9 - Power ON/OFF switch.
10 - Compartment with 2A phase and neutral protection fuses.
Carry out the following procedure step by step:

4.1) Connect the cables

– Connect the USB cable between the PC and the USB socket (7) on the rear of MG3.
– Check the supply voltage is correct then connect the power supply cable between socket (8) on the rear of MG3.
• Must be an EARTHED mains power supply.
• The electrical socket of power supply cable must be easily accessible.
4.2) Switch the machine ON
– Operate the ON/OFF switch (9) on the rear of MG3 to commence the start-up cycle.
When the GREEN LED (1) lights up, MG3 is ready for use.
• Do not press the BLUE button (4) before the GREEN LED lights up. If this happens restart MG3 (See section 7).
4.3) Install the GENIUSPRO operating software
– The "GENIUSPRO" CD provided with MG3 contains the driver and operating software required.
Facility to receive software updates from the internet (www.cembre.com) by direct connection or via network or portable
memory device.
4.4) Open/close the carriage
– Press the BLUE button (4) on the front of MG3 to open the carriage.
Press the button again to close the carriage.
• Ensure there is suffi cient space in front of MG3 to allow the carriage to open completely.
• Do not interfere with the carriage during opening and closing operations.

3. DESCRIPTION

6
5

4. INITIAL SET UP

. 5 .
SIDE
REAR
TG.1043 MG3 T
con testina Toshiba.
Dimensioni 90 x 60 mm
NOTA:
Nel campo S/N devono essere stampati numeri di matricola progressivi
7
Nel campo YEAR deve essere stampato l'anno richiesto
10
9
8