  • Page 1 61000 Series 04306120 BROAN MFG. CO., INC. 99042527A 926 W. State St. Hartford, WI 53027 - 1 -...
  • Page 2 READ AND SAVE THESE INSTRUCTIONS WARNING WARNING TO REDUCE THE RISK OF INJURY TO TO REDUCE THE RISK OF FIRE, ELEC- PERSONS IN THE EVENT OF A RANGE TRICAL SHOCK, OR INJURY TO PER- TOP GREASE FIRE, OBSERVE THE FOL- SONS, OBSERVE THE FOLLOWING: LOWING:* 1.
  • Page 3: Install The Ductwork

    INSTALL THE DUCTWORK ROOF CAP NOTE: To reduce the risk of fire, use only 6" ROUND steel ductwork. DUCT 1. Decide where the ductwork will run between the hood and the outside. DECORATIVE 2. A straight, short duct run will allow the hood WALL CAP FLUE to perform most efficiently.
  • Page 4: Connect Ductwork

    WIRING Note: This range hood must be properly WIRING BOX COVER grounded. The unit should be installed by a DUCT qualified electrician in accordance with all COLLAR applicable national and local electrical codes. 1. Remove the wiring box cover. Remove a knockout from the wiring box.
  • Page 5 CONNECT DUCTWORK UPPER   UPPER FLUE SECTION BRACKET Ductfree Configuration VENTS 1. Use screws and wall anchors (sup- (in upper flue section) plied) to secure the upper bracket to wall and ceiling as shown. DUCTFREE PLENUM 2. Turn upper flue section upside down so air vents are at the top.
  • Page 6: Maintenance

    MAINTENANCE Grease Filters The grease filters should be cleaned frequently. Use a warm detergent solution. Grease filters are dishwasher safe. Remove filters by pushing filters towards the back of hood and rotating filters downward. GREASE FILTERS Ductfree Filters The ductfree filters should be changed every 6 months.
  • Page 7: Operation

    OPERATION BLOWER LIGHT ON / OFF SWITCH BLOWER Controls SWITCH SPEED The hood is operated using the slide controls CONTROL under the front edge of the hood. The light switch turns the halogen lights on and off. The blower on / off switch turns the blower on to the running speed set by the blower speed PILOT LAMP...
  • Page 8: Warranty

    This warranty supersedes all prior war- ranties. To qualify for warranty service, you must (a) notify Broan at the address stated below or telephone: 1-800-637-1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part.
  • Page 9: Service Parts

    SERVICE PARTS 61000 SERIES RANGE HOOD KEY NO. PART NO. DESCRIPTION B02000191 Filter Spring B08087485 Grease Filter B02300730 Motor Capacitor B03295005 Terminal Box B02300722 Halogen Lamp Bulb B03292291 Switch Cover B03290377 Ductfree Filter Bracket B02310094 Motor B03295000 Blower Wheel B03202007...