The inverter has switched off due to
the electronics temperature being
too high.
-If the LEDs are flashing alternately,
the battery is nearly exhausted and
the nominal output is exceeded.
-If "overload" and "low battery" flash
simultaneously, the ripple voltage on
the battery terminals is too high.
The inverter switched off due to
excess ripple voltage on the battery
terminals.