Line Card Installation; Inserting A Line Card - Nortel 1200N User Manual

Broadband stp
Table of Contents

Advertisement

Modifications

Line Card Installation

Inserting a Line
Card
Centillion 1200N ATM Switch User Manual
NTP 297-8103-903
This section describes the procedures for installing a line card. It also describes the
procedures for installing a front plate over an idle line card slot.
Several types of line cards are available (listed below). They are all installed the
same way.
OC-12c-SMF(622 Mbps) (from November 1996)
OC-3c/STM-1 -MMF
SMF, -UTP-5 (155 Mbps)
TAXI-MMF(100 Mbps)
J2 (6.3 Mbps), DS3 (45 Mbps)
E3 (34 Mbps)
FR-DS1
CE-DS1
CE-E1
1.
Clean the connector with cleaner before inserting the line card.
2.
Each line card is equipped with ejectors. Close the ejectors before inserting
the card.
Figure 10-10: Line Card Ejectors - Closed Position
3.
Insert the line card all the way into the line card slot slowly and positively by
running the card through the guide rails. As shown in
Line Card Installation
Figure
10-11, securely
10-9