POSITIONING
n The Infinity 20 is an externally mounted, power flued appliance. IT MUST ONLY BE
FllTED OUTSIDE THE BUILDING.
H When determining a suitable position for the1 nfinity 20, the length of hot water pipe
runs should be taken into consideration. In principle, the Infinity 20 should be as
close as possible to the most often used taps, or in a central location between taps,
showers etc.
W Minimum mounting height from the ground is 1500mm.
n See diagram on page 21 for position of gas, water and power connections.
n The location of the flue terminal must comply with the clearances shown below.
/\
\
a - Below eaves, balconies or other projections:
Appliances over 50MJ h input
.
.
. . . . . . . . . . . . . . . . . . . .
b - From the ground or above a balcony
. . . .
.
.
c - From a return wall or external corner
.
.
.
.
d - From a gas meter (M)
.
.
.
.
.
.
.
.
e - From an electricity meter or fuse box (P)
.
.
f - From a drain or soil pipe
.
. .
. .
.
.
.
g - Horizontally from any building structure or obstruction facing a terminal . . . .
h - From any other flue terminal, cowl, or combustion air intake
. . . .
j - Horizontally from an openable window, door, inlet, or any other
opening into a building, with the exception
of sub-floor ventilation
. . . . . . . . . . . . . . . . . . . . . . . . .
.
Aust. 1500
k - From a mechanical air inlet, including a spa blower. . . . . . . . . . . . . . .
n - Vertically below an openable window, inlet or any other
opening into a building, with the exception of sub-floor
ventilation
.
.
.
.
.
.
.
. . . 500
.
1500
500
1000
.
500
150
. . . 500
500
N.Z. 500
1500
1500
Note: If you are unsure about clearances not indicated here, in Australia refer to
AG601 or your local authority. In New Zealand refer to DZ5261 or your local
authority.