Do you have a question about the Reu-VRM1120WD-E and is the answer not in the manual?
Questions and answers
עמוס
January 26, 2025
אין לי מספיק לחץ מים לא מרוצה מהמכשיר מה עושים
1 comments:
Mr. Anderson
February 10, 2025
If you have low water pressure with the Rinnai REU-VRM1120WD-E, check if your water supply pressure meets the minimum requirement of 1.2 bar at the appliance inlet. If the supply pressure exceeds 10 bar, install an approved pressure-reducing device. Keep in mind that high-temperature setpoints can reduce the available flow rate. If pressure remains low, inspect for possible restrictions or leaks in the water supply system.
Page 1
Service Manual Continuous Flow Water Heater Important. Read these instructions carefully before attempting installation or use of this appliance. All work must be carried out by competent persons.
Page 3
June 2010—Issue 1 This manual is intended for use by Gas Safe Regisetred Engineers...
TEMPERATURE CONTROLS - OPERATING Using 2 or more Universal Temperature Controllers. Switching the system ON. The hot water system and all controllers can be switched ON and OFF from any controller by pressing the ON/OFF button as shown. When the system is turned ON the water temperature display will be lit.
Page 13
TEMPERATURE CONTROLS - INFORMATION Do not push the ON/OFF button on the Temperature priority cannot be switched Master controller after transferring priority to another controller when the water is of temperature selection to a Secondary flowing through the water heater. controller as the system will shut down.
Page 26
Servicing ANNUAL SERVICE See Page 25 Isolate gas supply and electric supply Remove Front Panel by means of 4 corner screws Remove all screws around outer edge of manifold (11) and remove Inspect and clean injectors on inside of manifold (B). If heavily contami- nated remove front cover plate (A) and clean from inside out DO NOT RE-DRILL or ENLARGE ORIFICE Remove Ignition lead and Ionisation lead...
Page 27
Servicing Isolate water connections below heater Remove Filter (14) Inspect and clean as required Replace and re-instate water supply Remove gas valve (15) test nipple (K) and connect manometer Re instate Gas supply & Electric Supply Open water outlet and get maximum water flow possible Check burner pressure as per page 23 1.68 1.68...
Need help?
Do you have a question about the Reu-VRM1120WD-E and is the answer not in the manual?
Questions and answers
אין לי מספיק לחץ מים לא מרוצה מהמכשיר מה עושים
If you have low water pressure with the Rinnai REU-VRM1120WD-E, check if your water supply pressure meets the minimum requirement of 1.2 bar at the appliance inlet. If the supply pressure exceeds 10 bar, install an approved pressure-reducing device. Keep in mind that high-temperature setpoints can reduce the available flow rate. If pressure remains low, inspect for possible restrictions or leaks in the water supply system.
This answer is automatically generated