9. Disconnect the P7 (FP and FN) and P6 (F1 and F2)
connectors. See Figure 9-3.
10. Remove the four bolts to remove the exciter field.
See Figure 9-3.
11. Remove the three bolts and spacers from the
rectifier board.
1
4
1. P7 connector
2. P6 connector
3. F1 connector
4. Exciter field
Figure 9-3 Exciter Field Removal
1
1. Armature
2. Armature retaining bolt
3. Rotor leads
4. Rectifier board
Figure 9-4 Armature Removal
46
Section 9 Generator Disassembly/Reassembly
2
3
558864
2
3
4
558865
12. Disconnect the main field rotor leads from the
rectifier
board
Remove the bolt and washer.
13. Remove the armature from the shaft, guiding rotor
leads through the armature bores. See Figure 9-4.
14. Remove the tie wraps and disconnect the P5 (33,
44, 55, B1, and B2) wire connector.
15. Attach the hoist hook to the generator hoisting eye.
Note: The hoist capacity rating should be one-half
ton or greater.
16. Remove the two vibromount bolts. See Figure 9-5.
17. Raise the alternator end and place a wood block
under the locator plate. Lower the alternator until
the wood block supports the locator plate. See
Figure 9-5.
18. Remove the four overbolts from the end bracket.
See Figure 9-5.
1
5
4
1. P5 connector
2. Backplate
3. Wood block
4. Vibromount bolts
5. Overbolts
Figure 9-5 Supporting the Generator
positive/negative
terminals.
2
3
TP-6053 7/04