SERVICE PROCEDURE-1
PRIMARY CONNECTIONS FOR DIFFERENT VOLTAGES
AC Board Jumpers
For voltages in the 100V - 120V range, install the two jumpers marked L.
For voltages in the 200V - 240V range, install the single jumper marked H.
Main Transformer Jumpers
The following connections should be made for different line voltages.
TE
L 13942296513
www
.
http://www.xiaoyu163.com
100V :
K1-3 to TB1-4
P7
to TB1-3
P2
to TB1-2
K2-3 to TB1-12
P8
to TB1-11
P3
to TB1-10
110V :
K1-3 to TB1-6
P7
to TB1-5
P2
to TB1-2
K2-3 to TB1-14
P8
to TB1-13
P3
to TB1-10
120V :
K1-3 to TB1-8
P7
to TB1-7
P2
to TB1-2
K2-3 to TB1-16
P8
to TB1-15
P3
to TB1-10
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
200V :
K1-3
to TB1-4
TB1-2 to TB1-3
K2-3
to TB1-12
TB1-10 to TB1-11
220V :
K1-3
to TB1-6
Q Q
3
6 7
1 3
1 5
TB1-2 to TB1-5
K2-3
to TB1-14
TB1-10 to TB1-13
230V :
K1-3
to TB1-6
TB1-2 to TB1-7
K2-3
to TB1-14
TB1-10 to TB1-15
240V :
K1-3
to TB1-8
TB1-2 to TB1-7
K2-3
to TB1-16
TB1-10 to TB1-15