10 Service Mode

10.1. SERVICE CONTROL FUNCTION

You can check sensor temperature and comp. frequency during service function. Please refer to a service function section.During
the service function, damper thermostat is forcibly closed, and all fan motor is forcible operate except defrosting condition.
1. Sensor temperature of each compartment and out put signal of microcomputer.
Name of each compartment, sensor temperature, and output signal of microcomputer indicates on LED repeatedly.
• FC-Freezer compartment
• PC-Refrigerator compartment
• SC-Selectable compartment
• dC-Defrost sensor
• IC-Ice compartment
2. Compressor speed
DISPLAY
SPEED (r/m)
"C"→ "--" means compressor stop condition.
3. Exception of indicates
-41 °C or below(PC,SC,IC,FC,DEF. sensor) → "LL"
+41°C or above(PC,SC,IC,FC,DEF. sensor) → "HH"
0°C or below(AT sensor) → "1"°C
+50°C or above(AT sensor) → "50"°C
C24
C35
1440
2100
• AC-Ambient temperature
• C-Compressor speed
• Cd-Comp. integrated time(hh→mm)
Reset when defrosting
C42
C58
2520
3480
(Caution)
Indicated temperature is sensor's temperature.
These temperatures are different from temperature of
foods.
21
C69
C80
4140
4800