Sleeve And Manifold Installation; Method For Standard Walls - Rinnai rhfe-431ft Instruction Manual

Table of Contents

Advertisement

1.
Disassemble
Manifold from Sleeve.
The flue consists
of 3 parts,
sleeve,
inside
connectors
and tube,
outside
terminal; (disassemble
by pulling hard on
outside terminal
and inner connections,
then pull sleeve off outer terminal).
2.
Adjustment of Sleeve Length.
Measure
wall
thickness
through
previously drilled 80 mm hole.
End of sleeve should protrude 5-10 mm
from outside wall. Adjust sleeve length to
wall thickness
plus 5 -10 mm. (Sleeve is
threaded for adjustment).
3.
For A and AA flues only
Depending on flue set and wall thickness
extension
piece
"C" may need to be
removed.
Cut plastic, remove extension, then follow
instruction 2.
This applies to "A" and "AA" flues only.
There is no extension
on other flues, they
can be fully adjusted by turning the
threaded section.
4.
Fixing Sleeve.
Fix to the wall,
using
the 3 screws
provided.
NOTE:
The flange
is marked "TOP",
sleeve
must be fitted with this mark UP.
Check sleeve protrudes
5-10 mm on
the outside.
Extension joint
under plastic
Extension
("A" and "AA" flues only)
1 Adjust length by turning sleeve.
Remove extension at this
pointif necessary.
5-W mm
Don? remove Oreen plastic cover@ from sleeve.
-25-