HP StoreOnce 4700 Backup Service And Maintenance Manual page 18

Hide thumbs Also See for StoreOnce 4700 Backup:
Table of Contents

Advertisement

p1224 Storage System
p1224 Storage System
# hardware show status 02358fe6-0000-1000-b012-53344230334b
Name
--------------------
p1224 Storage System
-
Drawer 1
Pools
Controller 1
# hardware show status 50014380254FAD32
Name
-----------------------
-
Disk 5000C50055C1BB0B
-
3.
When you reach the faulty component, use the following command to display details and
look at the diagnostic message for more information.;
hardware show status <Dev-id> details
For example:
# hardware show status 50014380254FAD32 details
Name
----------------------------------------------
-
Dev-id
Status
message
type
model
serialNumber
firmwareVersion = -
location
Disk 5000C50055C1BB0B
Dev-id
Status
message
type
model
serialNumber
firmwareVersion = HPD8
location
volumeName
capacity
-
Dev-id
Status
message
type
model
serialNumber
firmwareVersion = -
location
volumeName
capacity
18
Identifying problems
02358fe6-0000-1000-b012-53344230334b
010e9a23-0000-1000-b01c-533442303034
Dev-id
------------------------------------
02358fe6-0000-1000-b012-53344230334b
50014380254FAD32
500143802050F740
pools-1
50014380254FAD30
Dev-id
----------------------
50014380254FAD32
5000C50055C1BB0B
Drive_Missing_b1000103
= 50014380254FAD32
= DEGRADED
= -
= driveEnclosure
= ServBP 4
= -
= -
= 5000C50055C1BB0B
= OK
= -
= drive
= MM1000FBFVR
= 9XG3601K00009316ZLN0
= Port: 1I Box: 2 Bay: 1
= LUN 1
= 1.00 TB
= Drive_Missing_b1000103
= FAILED
= The drive has failed.
= drive
= -
= -
= Port: 1I Box: 2 Bay: 2
= LUN 1
= 1.00 TB
DEGRADED
OK
Status
--------
DEGRADED
DEGRADED
DEGRADED
DEGRADED
OK
Status
--------
DEGRADED
OK
FAILED