Hytera MD78X Service Manual page 548

Hide thumbs Also See for MD78X:
Table of Contents

Advertisement

Service Manual
VHF (136-174MHz 25W) Information
Description of Normal Situations:
[1] The current in analog mode is above 6A under 45W power supply and above 1A under 5W.
However, in digital mode, the current will be reduced by 50%.
[2] The APC voltage should be above 2V at TP811.
[3] Check whether there is an appropriate TX LO signal at TP803.
[4] Check whether the gain is 20dB and the input signal is 0dBm at Q805.
[5] Check whether the gain is 14dB and the input signal is 0dBm at Q804.
[6] Check whether the gain is 10dB and the input signal is 0dBm at Q802 and Q803.
535

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Md78xg

Table of Contents