Loc Var Ddm/Ddm Sweep Amplitude Control; Khz Ref Level Control; 30 Hz Var Level Control; Loc Ddm Sweep Switch - IFR NAV-402AP-3 Operation Manual

Ramp test set
Table of Contents

Advertisement

ITEM
DESCRIPTIO N
24. LO C
VAR
AMPLITUDE Contr ol
Contr ols var iable Localizer DDM/DDM
sweep amplitude when the LO C DDM
Contr ol is set to ↓ and accor ding to
LO C DDM SWEEP Switch setting:
G LO C DDM SWEEP Switch set to O .
Continuously var ies LO C pointer
deflection fr om ccw 0.4 DDM ( left)
thr ough 0 DDM to cw
0.4 DDM ( r ight) .
G LO C DDM SWEEP Switch set to
AL, S or AR.
Sets the maximum DDM
deflection/sweep amplitude fr om 0
to 30 µ A ( ± 0.0155 DDM) for an
automatic LO C DDM sweep.
25. 9.96 kHz REF LEVEL Contr ol
Adjusts modulation per centage of the
9.96 kHz VAR tone ( par t of VO R
composite signal) fr om 0 to 30%. The
9.96 kHz VAR LEVEL Contr ol ( outside
lar ger
knob)
tur ned past 30 to the stop.
26. 30 Hz VAR LEVEL Contr ol
Adjusts modulation per centage of the
30
Hz
VAR
composite signal) fr om 0 to 30%. The
30 Hz VAR LEVEL Contr ol ( inside
smaller
knob)
tur ned past 30 to the stop.
O P E R AT I O N M A N U A L
I FF - 7 0 1 T i
DDM/DDM
SWEEP
r eaches
30%
when
tone
( par t
of
VO R
r eaches
30%
when
ITEM
DESCRIPTIO N
27. LO C DDM SWEEP Switch
Sets the Localizer sweep mode:
G O allows manual sweep or var iable
DDM adjusted by LO C VAR
DDM/DDM SWEEP AMPLITUDE
Contr ol.
G AR ( ar m r ight) or AL ( ar m left)
initializes inter nal sweep cir cuit to
0 DDM and deter mines initial
sweep dir ection pr ior to selecting
sweep mode ( S) .
G S initiates automatic LO C DDM
sweep beginning at 0 DDM and
deflecting to the dir ection
accor ding to the pr ior ar ming
setting ( AR or AL) . The sweep
continues to the maximum pointer
deflection deter mined by the LO C
VAR DDM/DDM SWEEP
AMPLITUDE Contr ol setting. The
sweep r ever ses and continues to
the maximum pointer deflection in
the other dir ection. The sweep is
symmetr ical r elative to 0 DDM.

28. PWR/BAT Switch

Two position switch contr ols power to
the Test Set:
G PWR connects Test Set to ac line
power connected to AC IN
Connector .
G BAT connects or disconnects Test
Set fr om inter nal Batter y.
Connecting the Test Set to the
Batter y activates an inter nal
batter y timer . Test Set oper ation
disconnects fr om the inter nal
Batter y after r eaching the inter nal
batter y timer limit ( ≈ 6 to 10
minutes) or by pr essing the
PWR/BAT Switch to BAT to
disconnect.
1- 2- 2
Page 9
Jul 1/00

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for IFR NAV-402AP-3

Table of Contents