Troubleshooting; If The Enclosure Does Not Initialize; Diagnostic Steps; Is The Enclosure Front Fault Led Amber - HP StorageWorks D2700 User Manual

Hide thumbs Also See for StorageWorks D2700:
Table of Contents

Advertisement

7 Troubleshooting

If the enclosure does not initialize

IMPORTANT:
After a power failure, the system automatically returns to the last-powered state (On or Off) when
A/C power is restored.
1.
Ensure that the power on/standby button was pressed firmly and held for approximately three
seconds.
2.
Verify that the power on/standby button LED is green.
3.
Verify that the power source is working:
a.
Verify that the power supplies are working by viewing the power supply LEDs. If necessary,
remove and reinstall the power supplies to verify that they are seated properly.
b.
Remove and inspect AC power cords from both power supplies and reconnect them.

Diagnostic steps

Is the enclosure front fault LED amber?

Answer
No
Yes
Possible Reasons
System functioning properly.
Front Status and UID module
might not be inserted properly,
might have a damaged connect-
or, or might have failed.
Possible error condition exists.
D2600/D2700 Disk Enclosure User Guide
Actions
No action required.
Be sure that the Front Status and
UID module is undamaged and
is fully seated.
Check rear fault LEDs to isolate
failed component.
Contact an authorized service
provider for assistance.
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks d2600

Table of Contents