10.5. Connect The Cable To The Outdoor Unit

1. Remove the control board cover metal from the unit by
loosening two screws.
2. Cable connection to the power supply through isolating
Devices (Disconnecting means).
• Connect approved type polychloroprene sheathed
power supply cord 3 x 2.5 mm
designation or heavier cord to the terminal board, and
connect the others end of the cord to Isolating Devices
(Disconnecting means).
3. Connecting cable between indoor unit and outdoor unit
shall be approved polychloroprene sheathed 4 x 1.5 mm
flexible cord, type designation 245 IEC 57 or heavier
cord.
5. For wire stripping and connection requirement, refer to the diagram below.
6. Secure the power supply cord and connecting cables onto the control board with the holder.
7. Attach the control board cover back to the original position with screw.
This equipment must be properly earthed.
• Note: Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
• Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
2
245 IEC 57 type
2
31
4. Connect the power supply cord and connecting cable
between indoor unit and outdoor unit according to the
diagram as shown.