Servicing; General Servicing; Repairs At The Unit; Tempspray-H326 And Tempspray-H226 - WAGNER TempSpray-H126 Operating Manual

Hide thumbs Also See for TempSpray-H126:
Table of Contents

Advertisement

Available languages

Available languages

GB
servIcIng / repaIrs at the unIt
8

SerViciNG

8.1

GeNeraL SerViciNG

After the regulations of the Accident Pre-
vention & Insurance Association an annual
expert check is required- inclusive confirma-
tion .
You can servicing of the unit carried out by
the Wagner Service. Favourable conditions
can be agreed with a service agreement and/
or maintenance packages.
Minimum check before every startup:
1. Check the high-pressure hose, power supply cable with
plug for damage.
Inspect the high-pressure hose visually for any notches or
bulges, in particular at the transition in the fittings.
check at periodical intervals:
1. The coupling nuts have to be clearly rotatable. The conduc-
tivity has to be less than 1 Mega Ohm (Tempspray-H326,
Tempspray-H226 and Tempspray-H426) alternatively less
than 2 Ohm (TempSpray-H126) over the whole length.
2. Check the status of the heating conductor
To do this, press and hold down the "START" and
buttons simultaneously, and also press the
If "0A" appears in the display, the heating conductor is ok.
If a different value is shown for "A" (e.g. 5A), please contact
Wagner Service to arrange for an insulation test.
3. The isolation of the heating wire has to be tested with an
insulation tester with at least 1000V.
Have all the electric tests carried out by the
Wagner Service.
9

rePairS aT THe uNiT

Switch the unit off.
Before all repair work: Unplug the power
plug from the outlet.
Due to necessary custom tools repairs on the heating wire and
the heating wire feed have to be done only by the Wagner-
Service.
A replacement of the heating-hose should, due to its internal
heating wire, only be done from the Wagner-Service as well.
The hose whips of the TempSpray-H326 and TempSpray-H226
can be replaced without any problems.
42
TempSpray-H326 / -H226 / -H126/ -H426
9.1

TeMPSPray-H326 aND TeMPSPray-H226

cHaNGiNG THe POWer cOrD

1. Dismount the hose reel (1) by loosening the 2 screws (2)
on the carriage (3).
2. Lever the plastic cover (4) off with a screwdriver.
3. Release cable connexion (5).
Disconnect the power cable from the terminal strip (6).
4. Replace power cord (fix green-yellow conductor to PE-
marked terminal).
(Only use a licensed power cord with the marking H07-
RNF and with a splash water proof plug)
5. Mount plastic covers carefully.
6. Fix hose reel to the carriage again.
1
button.
Switch the unit off.
Before all repair work: Unplug the power
plug from the outlet.
Work or repairs at the electrical equipment
may only be carried out by a skilled electri-
cian. No liability is assumed for incorrect in-
stallation.
3
2
6
4
5