Chapter 3 Basic Operations — Switching on/off the projector
Initial setting (operation setting)
Set the items for the operating method depending on the projector's application and duration of usage.
After completed the initial setting, you can change the settings of each item from the [PROJECTOR SETUP]
menu → [OPERATION SETTING]. If you change the settings while using the projector, the duration until the
luminance of the light source decreases by half may shorten or the luminance may decrease.
This initial setting (operation setting) is prepared to complete the settings at once during the installation when
the operation of the projector is predetermined. When the [PROJECTOR SETUP] menu → [INITIALIZE] →
[ALL USER DATA] is executed, do not change the setting in the initial setting (operation setting), but press the
<ENTER> button and proceed to next initial setting (installation setting). If you need to change the setting, ask the
person responsible for this projector (such as a person in charge of equipment or operation).
Note
f The preceding initial setting screen is displayed when the projector is switched on for the first time after purchase. If the [PROJECTOR
SETUP] menu → [INITIALIZE] → [ALL USER DATA] is executed, the settings before execution are displayed in [OPERATING MODE] and
[MAX LIGHT OUTPUT LEVEL].
f For the relationship between the luminance and the runtime, refer to "Interrelation of luminance and runtime" (x page 63).
f For details on each setting item, refer to the [PROJECTOR SETUP] menu → [OPERATION SETTING].
1)
Press as to select [OPERATING MODE].
2)
Press qw to switch the item.
f The items will switch each time you press the button.
f Set [OPERATING MODE] to anything other than [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3] when
using the projector at an altitude of 2 700 m (8 858') or higher above sea level.
f Set [OPERATING MODE] to anything other than [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3] when
using the optional Smoke Cut Filter (Model No.: ET-SFR330).
[HIGH]
*1
[NORMAL]
*1
[LONG LIFE1]
*1
[LONG LIFE2]
*1
[LONG LIFE3]
*1
[USER1]
[USER2]
[USER3]
*1 The runtime is an estimation when the [PICTURE] menu → [DYNAMIC CONTRAST] is set to [3].
f Proceed to Step 5) when [NORMAL], [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3] is selected.
3)
Press as to select [MAX LIGHT OUTPUT LEVEL].
4)
Press qw to adjust.
Operation
Press w.
Press q.
62 - ENGLISH
INITIAL SETTING
OPERATING MODE
MAX LIGHT OUTPUT LEVEL
LIGHT OUTPUT
Set the way to use the projector. For details, please
refer to the operating instructions "When the initial
setting screen is displayed".
MENU SELECT
SET
ENTER
The life of the light source will shorten compared to [NORMAL], but set this item when a higher
luminance than [NORMAL] is required. The estimated runtime is approximately 8 000 hours.
Set this item when high luminance is required. The estimated runtime is approximately 20 000 hours.
(Factory default setting)
The luminance will decrease compared to [NORMAL], but set this item to increase the expected life of
the light source. The estimated runtime is approximately 43 000 hours.
The luminance will decrease compared to [LONG LIFE1], but set this item to increase the expected
life of the light source. The estimated runtime is approximately 61 000 hours.
The luminance will decrease compared to [LONG LIFE2], but set this item to increase the expected
life of the light source. The estimated runtime is approximately 87 000 hours.
Set [MAX LIGHT OUTPUT LEVEL] and [LIGHT OUTPUT] individually.
Adjustment
Increases the maximum level of brightness correction.
Decreases the maximum level of brightness correction.
2/7
NORMAL
83.3%
83.3%
CHANGE
Range of adjustment
8.0 % - 100.0 %