Press the <ENTER> button.
f The [STATUS] screen is displayed.
3)
Press qw to switch the pages.
f The page will change each time you press the button.
[PROJECTOR TYPE]
[PROJECTOR RUNTIME]
[LIGHT RUNTIME]
[MAIN/SUB VERSION]
[INTAKE AIR TEMP.]
[OPTICS MODULE TEMP.]
[EXHAUST AIR TEMP.]
[LIGHT1-B TEMP.]
[LIGHT1-S TEMP.]
[LIGHT2-B TEMP.]
[LIGHT2-S TEMP.]
[SELF TEST]
[INPUT]
[SIGNAL NAME]
[MEMORY NO.]
[BACKUP INPUT STATUS]
[NUMBER OF REGISTERED
SIGNAL]
[COOLING CONDITION]
[ATMOSPHERIC PRESSURE] Displays the atmospheric pressure.
[REMOTE2 STATUS]
[AC VOLTAGE]
[ON COUNT]
[FILTER TYPE]
[FILTER COUNTER]
[OPERATING MODE]
[HIGH]
[NORMAL]
[LONG LIFE1]
[LONG LIFE2]
[LONG LIFE3]
[USER1]
[USER2]
[USER3]
[CONSOLIDATED RUNTIME]
[UPGRADE KIT]
Chapter 4 Settings — [PROJECTOR SETUP] menu
Displays the projector type and serial number of the projector.
Displays the runtime of the projector.
Displays the runtime of the light source 1 and the light source 2.
Displays the main and sub versions of the firmware of the projector.
Displays the status of the intake air temperature of the projector.
*1
Displays the status of the internal temperature of the projector.
*1
Displays the status of the exhaust air temperature of the projector.
*1
*1
Displays the light source 1 temperature status of the projector.
*1
*1
Displays the light source 2 temperature status of the projector.
*1
Displays the status of the projector.
Displays the input terminal currently selected.
Displays the representative input terminal when one image is displayed with multiple input signals.
Displays the input signal name.
Displays the memory number of the input signal.
Displays whether switching to the backup input signal is possible or not when [BACKUP INPUT
MODE] is set to [OFF]. (x page 116)
Displays the number of registered signals.
Displays the set cooling conditions.
Displays the control status of the REMOTE2.
Displays the input supply voltage.
[POWER ON TIMES]
[MECHANICAL SHUTTER]
Displays the setting of the [PROJECTOR SETUP] menu → [FILTER SETTING] → [FILTER TYPE].
Displays the runtime of the filter (counter numeric value) and the recommend time to replace the filter.
*2*3
Displays the setting value of the [PROJECTOR SETUP] menu → [OPERATION SETTING] →
[OPERATING MODE].
Displays the runtime of the light source with [OPERATING MODE] set to [HIGH].
Displays the runtime of the light source with [OPERATING MODE] set to [NORMAL].
Displays the runtime of the light source with [OPERATING MODE] set to [LONG LIFE1].
Displays the runtime of the light source with [OPERATING MODE] set to [LONG LIFE2].
Displays the runtime of the light source with [OPERATING MODE] set to [LONG LIFE3].
Displays the runtime of the light source with [OPERATING MODE] set to [USER1].
Displays the runtime of the light source with [OPERATING MODE] set to [USER2].
Displays the runtime of the light source with [OPERATING MODE] set to [USER3].
Converts the total runtime of the light sources with [OPERATING MODE] set to each item into the
time used with the [NORMAL] setting.
*4
The converted runtime is used for a rough indication about when to perform maintenance when the
projector is used in combination of each item in [OPERATING MODE].
[ET-UK20]
[ET-CUK10]
Displays the number of times the power is turned on.
Displays the number of times the mechanical shutter is closed.
It is counted when [MECHANICAL SHUTTER] is set to [ENABLE].
Displays the activation status by the Upgrade Kit (Model No.:
ET-UK20).
Displays the activation status by the Auto Screen Adjustment
Upgrade Kit (Model No.: ET-CUK10).