INSTALLER AND OWNER GUIDE
end simply make sure that the end fits into the screws that secure the fascia to the
heater. If the end is too small then the end will spin and damage the screw.
1 off Flat end screwdriver. This is required on both models. The end should fit into the
slot head screws supplied with the heater.
2. For drilling into brickwork you will need an electric drill (preferably with hammer
action) and appropriate size drill bit for the wallplugs supplied (See figure 3).
Where can I fit the heater?
This heater can be fitted into fireplaces or surrounds where the following dimensions
are available.
Width
Height
Depth
There should be at least 30mm (1.2 inches) clearance between the top of the fascia and
anything such as a shelf, fireplace surround or mantel etc. This will allow the fascia to
be lifted off or removed during servicing. To check this gently place the fascia against
the surface to which it is to be fixed. Measure the distance from the top of the fascia.
The heater is of a slim design and should suit most fireplace openings and fire
surrounds. However, there may be some applications that require the need for a spacer
where a fireplace opening or fireplace surround opening are not available i.e. a flat wall.
Some models are not supplied with a spacer frame kit. This optional spacer frame kit is
obtainable either from the your heater supplier or direct from Baxi Fires Division Sales.
The kit is:
Models with traditional fascia - 75mm (3 inch) spacer kit (Kit number 05801T1).
!
Important Electrical Safety
The heater must not be located in front of or under an electrical socket, the socket must
always be accessible in order to disconnect the heater from the electrical supply for
maintenance and cleaning.
Important! This heater must be earthed.
The heater is supplied with a 3 pin 13 Amp fused re-wireable plug with 1mm² 3 core
!
cable.
The wires in the cable are coloured in accordance with the following code: -
!
Live =Brown
The mains supply must be safely routed from the heater to an electrical socket.
!
390mm - 450 mm (15.35 inches - 17.72 inches)
555mm - 590 mm (21.9 inches - 23.2 inches)
At least 75mm (At least 3 inches)
Neutral = Blue
Page 5
Earth = Green /Yellow