Shield Terminator Repair; Nickel-Plated Shield Terminator Preparation; Nickel-Plated Shield Terminator Repair - Bell OH-58A Technical Manual

Table of Contents

Advertisement

WINDOW STRIP
END STRIP
END STRIP BRAID FOLDED BACK

Shield Terminator Repair

Figure 11-19.
11-11.
TERMINATORS FOR NICKEL-PLATED
SHIELDS (INCLUDING VERMILLION).
GENERAL INFORMATION: The kit contains
shield terminators for nickel-plated
shields, including vermillion.
This is a permanent repair.
LIMITATIONS:
PERSONNEL/TIME REQUIRED:
1 Soldier
15 Minutes
MATERIALS/TOOLS
REQUIRED:
Shield Terminator (item 10, Appx B)
Reflector (A3) (item 10, Appx B)
Heat Gun/Heat Source
Stripper or Knife
Insulating Sleeve (item 10, Appx B)
PROCEDURAL STEPS:
Prepare cable
for repair.
1.
Figure 11-20.
2.
Position ground lead and shield ter-
minator as shown in Figure 11-21.
3.
Heat shield terminator until solder
ring melts; then, continue heating for an
additional 15 seconds or until sleeve
starts to turn brown.
with temperature set at 900°F.
4.
Terminate the ground lead as
directed in the aircraft wiring manual.
5.
Record BDAR action taken.
mission is complete, as soon as
practical, repair the equipment/system
using standard maintenance procedures.
.25-.30"
WINDOW STRIP
Figure 11-20.
Refer to
Figure 11-21.
TM 55-1520-228-BD
ELECTRICAL AND AVIONICS SYSTEM
Use reflector
END STRIP
Nickel-Plated Shield
Terminator
Preparation
Nickel-Plated Shield
Terminator Repair
When
.25-.30"
11-25