Electrical
• The Electrical installation must be carried out by a qualified electrician in
accordance with the current edition of the I.E.E. Wiring Regulations.
• Only connect the appliance to a single phase supply with a mains voltage
as specified on the rating plate.
• Means for electrical disconnection must be incorporated in the fixed wiring
in accordance with the wiring rules.
• This unit is supplied pre-wired. If the cable needs replacing, it must be replaced
with a correctly rated cable and any work should be carried out by a competent
person.
• In order to avoid a hazard due to inadvertent resetting of the thermal cut-out,
this appliance must not be supplied through an external switching device
such as a timer or connected to a circuit that is regularly switched on and
off by the utility.
The unit is fitted with an auto-reset thermal cut-out which will operate for
safety reasons in the event of the unit overheating. To reset the thermal
cut-out switch off the power to the unit and allow it to cool down. Ensure
the unit is full and then switch the unit back on. The thermal cut-out should
reset itself.