Goodman GMVM Service Instructions Manual page 57

96% modulating gas furnaces & accessories
Table of Contents

Advertisement

OPERATION
F
M
AN
ODE
C
T
ONVENTIONAL
HERMOSTAT
Two seconds after G request becomes active without Y1 re-
quest, IFC will run the circulator at the appropriate speed (as
selected by the DIP switches), unless circulator is running
as a result of Heat or Cool mode. The circulator speed re-
quired by the heat or cool demand always has priority over G
speed.
C
T
OMMUNICATING
HERMOSTAT
If a conventional G request is present without a heat or cool
request from the communicating thermostat, the circulator
will run at the selected fan speed.
H
C
UMIDITY
ONTROL
H
O
– C
UMIDIFIER
UTPUT
ONVENTIONAL
One set of isolated relay contacts are wired to a pair of termi-
nals for connection to a humidifier. When the inducer is on
the IFC closes the humidifier relay contacts, except from the
calibration routine where the humidifier relay contacts are
always open.
H
O
– C
UMIDIFIER
UTPUT
OMMUNICATING
One set of isolated relay contacts are wired to a pair of termi-
nals for connection to a humidifier. Upon receipt of a Humidi-
fication Requested Demand the IFC will:
Close the humidifier relay contacts
Energize the circulator at the circulation speed (G
speed) unless the circulator is commanded to a differ-
ent speed by a heat demand.
Dehumidification – Conventional Thermostat
DEHUM functionality is enabled by a DIP switch set-
ting.
The IFC varies circulator speed operation based on the
DEHUM signal from the thermostat
If 24VAC (R) is not connected to DEHUM (through a
Humidistat) and both Y1 and O terminals are ener-
gized, then the IFC control reduces the cooling CFM
by 15%.
If both Y1 and O terminals are not energized, the
DEHUM signal is ignored
DEHUM is ignored during any heating request.
L
P
-B
EARN
USH
UTTON
Pressing the learn button re-sets the communicating net-
work and allows the IFC to search for communicating equip-
ment The press and release of the button starts the same
learning process as during power-up of the system.
T
HERMOSTAT
T
HERMOSTAT
C
T
™ C
LIMATE
ALK
OMMUNICATION
The IFC has two LEDs :
Red communications LED – Indicates the status of
the network
OFF is normal condition.
2 slow flashes on power-up: ON for ¼ second, OFF for
¾ second, ON for ¼ second, OFF.
Continuous slow flash indicates communication fail-
ure: ON for ¼ second, OFF for ¾ second...
Green receive LED – Indicates network traffic
Fast, sporadic flashes indicates normal bus commu-
nication.
ON solid indicates a Data 1 / Data 2 miswire.
Model
Tap
*CVM960604CX*
C
D
*CVM960805DX*
C
D
*CVM961005DX*
C
D
*MVM960603BX*
C
D
*MVM960805CX*
C
D
*MVM961005DX*
C
D
*MVM961155DX*
C
D
*100% CF M shown. CFM will vary proportionally with the gas valve
BTU/H input.
Airflow Table
LED
S
Low
High
10 0%
Stage
Stage
Heat
Cool
Cool
*CFM
A
370
660
1220
B
540
860
1340
790
1 150
1460
980
1 470
1590
A
530
900
1600
B
730
1 100
1710
930
1 430
1800
1220
1 880
1910
A
500
780
1730
B
740
1 070
1770
920
1 380
1840
1160
1 780
1870
A
390
630
9 50
B
550
800
1050
680
1 000
1170
800
1 210
1270
A
540
830
1600
B
750
1 090
1690
980
1 460
1800
1210
1 800
1890
A
510
790
1810
B
710
1 100
1850
910
1 410
1890
1160
1 830
1940
A
510
790
1810
B
710
1 100
1850
910
1 410
1890
1160
1 830
1940