Goodman GMVM Service Instructions Manual page 10

96% modulating gas furnaces & accessories
Table of Contents

Advertisement

ACCESSORIES
EXTERNAL FILTER RACK (EFR01 )
Used on 96% Upflow Modulating Furnaces
CONCENTRIC VENT CONVERSION KIT ( DCVK-20 DCVK-30)
T
he DCVK-20 (2") or the DCVK-30 (3") is a concentric vent
kit approved with furnaces listed in this manual.
This concentric vent kit allows for vertical or horizontal vent
termination. The illustrations give a brief view of the kit and
its application.
Strap
(Field Supplied)
Vent
45 Elbow
Combustion Air
(Field Supplied)
DCVK
(Horizontal Installation)
SIDE WALL VENT KIT (0170K00000S)
This side wall only vent kit #0170K00000S is to be used
with 2" - 3" vent systems. This kit is NOT intended for use
with single pipe (indirect vent) installations.
The vent kit must terminate outside the structure and may
be installed with the intake and exhaust pipes located side-
by-side or with one pipe above the other.
See the section in this manual under "Vent Flue and Com-
bustion Air Pipe Terminations" for more information or con-
sult the Installation Instructions (IO-635).
SIDE WALL VENT KIT (0170K00001S)
This side wall only vent kit #0170K00001S is to be used
with 2" vent systems. This kit is NOT intended for use with
single pipe (indirect vent) installations.
10
See the section in this manual under "Vent Flue and Com-
bustion Air Pipe Terminations" for more information or con-
sult the Installation and Operating Instructions (IO-619*).
Combustion Air
Vent
Flush to
1" maximum
The vent kit must terminate outside the structure and may
be installed with the intake and exhaust pipes located side-
by-side or with one pipe above the other.
See the section in this manual under "Vent Flue and Com-
bustion Air Pipe Terminations" for more information or con-
sult the Installation Instructions (IO-805).
SLOTS IN FILTER
UNIT SIDE
PANEL
FRONT
OF UNIT
BASE
OF UNIT
RETURN AIR
CUTOUT AREA
Vent
Combustion Air
Roof Boot/Flashing
(Field Supplied)
Vent
DCVK
(Vertical Installation)
CLEAR SCREWS
ON UNIT
BLOWER DECK
SCREWS
FILTER RACK ASSEMBLY
(FACE FILTER OPENING
TOWARDS FRONT
OF UNIT)
LOWER EDGE
SCREW
Maintain 12" (18" for Canada)
minimum clearance above highest
anticipated snow level. Maximum of
24" above roof.
Support (Field Supplied)
45 Elbow
(Field Supplied)
Combustion Air
H o riz o n ta l Insta lla tio n
V e rtical In sta lla tio n

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

AcvmGcvmAmvm

Table of Contents