EFOY COMFORT80 Installation Manual page 12

Methanol fuel cell
Table of Contents

Advertisement

Mounting Instructions
When choosing a location in which to install the fuel cell, please
remember that the permitted operating temperature range for the device
is –20°C to +40°C, while the storage temperature must be between +1°C
and +45°C.
CAUTION!
The device generates waste heat and waste gases.
The waste heat and gases must be released into the open air.
1.
2.
>5 cm
>10cm
>10cm
>5 cm
Supply air
Exhaust air
The space in which the device is to be
installed (incl. M10 fuel cartridge and
safety distance) must be at least 68 x
38 x 34 cm.
To ensure circulation of air, the
opening for the fresh-air supply must
not be located directly in front of the
fuel cell's fresh-air supply.
The opening for the fresh-air supply
must be at least 80 cm
cm² for the EFOY Comfort 210).
A gap of at least 5 to 10 cm must be left
between the device and the panels
enclosing the installation space.
The air supply or fresh-air supply must
not be blocked by the fuel cartridge.
Install the device in an upright position
only. Use the mounting plate provided
for installation.
2
(or at least 160
Page 35