Changing Default Programming; Engineer Program Command List - Scantronic 9448 Plus Installation And User Manual

Alarm control panel
Hide thumbs Also See for 9448 Plus:
Table of Contents

Advertisement

Changing Default Programming

Changing Default Programming
To change the factory defaults, the panel must be in programming mode.
Then:
1.
Key in a two digit programming command followed by "ENTER". (See

"Engineer Program Command List".)

On commands 35 to 68 a LED will glow to show you the current option
used in the command. If the LED is OFF the option is "0".
2.
Key in the correct digit for the option you want, and then press ENTER.
The panel beeps twice to show that it has accepted the command. All
the LEDs flash, and the panel is ready for the next command.
The panel gives a single error tone if you enter an incorrect command.
Re-enter the correct command.
3.
Key in "99 ENTER" to leave programming mode when you have fin-
ished. You will then be in user mode.
Engineer Program Command List
To change:
Zones omitted in
Part Set*
Chime
Zones Not Used
Engineer Code
User Code 1
User Code 2
Silent Part set
Zone 2 Entry
Route
Auto Re-Arm
Bell Time
To change:
8 of 12
Key-in:
followed by:
10
zone n..n
ENTER
11
zone n..n
ENTER
15
zone n..n
ENTER
20
new code
ENTER
21
new code
ENTER
22
new code
ENTER
35
0
ENTER
ENTER
1
ENTER
36
0
ENTER
ENTER
40
1
ENTER
ENTER
2
ENTER
3
ENTER
4
ENTER
42
1
ENTER
ENTER
2
ENTER
3
ENTER
4
ENTER
Key-in:
followed by:
496328 Issue 2
Notes
LEDs ON for zones
ENTER
omitted (see note 1)
LEDs ON for chime
ENTER
(EE zone = zone 7)
LEDs OFF for zone
ENTER
not used (see note 2)
4 digits
ENTER
4 digits (see note 3)
ENTER
4 digits (see notes 3 & 4) 0000
ENTER
Audible
Silent
Normal Alarm
1
ENTER
Never rearm
Rearm once
Rearm twice
Rearm three times
90 seconds
3 minutes
10 minutes
20 minutes
Notes
9448+/9448ES
Defaults
none
none
none
7890
1234
y
y
Entry Route
y
y
Defaults

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9448es

Table of Contents